1151/3051壓力變送器

工作原理
1151/3051系列智能電容式壓力變送器檢測部分是一個(gè)可變電容,稱為"δ"室,被測壓力作用在"δ"室兩側(cè)隔離膜片上,通過隔離膜片和"δ"室內(nèi)灌充液傳至中心膜片.中心膜片是具有伸縮性的彈性元件,
與兩側(cè)絕緣體的極板各組成一個(gè)電容,隨著被測壓力的變化中心膜片產(chǎn)生相應(yīng)的位移變化,這種位移變化轉(zhuǎn)變?yōu)殡娙輼O板上的差動電容.改電容量的變化值與被測壓力的變化成正比.通過檢測差動電容的大小,轉(zhuǎn)換為線性的電信號. "δ"室的結(jié)構(gòu)圖如下:
功能參數(shù)
使用對象:液體.氣體和蒸汽
測量范圍:0.5~40000Kpa(詳見型號規(guī)格表)
輸出信號: 4-20mA(可輸出開放信號) 與HART協(xié)議兼容的數(shù)字信號
供電電源:12~45VDC,一般工作電源為24VDV
負(fù)載特性:與供電電源有關(guān)(見圖),負(fù)載阻抗RL與電源電壓VS關(guān)系式:
                 RL≤50(VS-12)
溫度范圍:電子組件:-30~70℃
         灌充硅油:- 30~104℃
         法蘭式或灌充高溫硅油:15~315℃
顯   示:1.智能LCD顯示(顯示器工作溫度-25~70℃)
       2.31/2位LCD(顯示器工作溫度-25~65℃)
       3.指針式表頭(工作溫度-30~80℃)
量程零位:外部連續(xù)可調(diào)
正負(fù)遷移:差壓變送器:最大正遷移為500%,最大負(fù)遷移為600%
         壓力變送器:最大正遷移為500%,最大負(fù)遷移不大于大氣壓
         絕壓變送器:最大正遷移為500%,不可負(fù)遷移
過載壓力:不超過規(guī)定壓力的1.15倍
阻尼時(shí)間:0.2~1.67s可調(diào)
防    爆:隔爆型dⅡBT4  本安型iaⅡCT6
防    護(hù):IP65
技術(shù)參數(shù)
(不帶遷移,標(biāo)準(zhǔn)工作條件下,充硅油,隔離膜片為316L)
精度等級:0.1% 0.25%
穩(wěn)定性:六個(gè)月內(nèi)不超過變送器精度
溫度影響:在最大量程時(shí),每10℃變化見下表
量程代號
精度等級
0.1級
0.25級
1
/
/
2
下限:≤±0.3% 量程≤±0.5%
下限:≤±0.5%  量程≤±1%
3~8
下限:≤±0.15% 量程≤±0.25%
下限:≤±0.25% 量程≤±0.5%
振動影響:任何方向上振動頻率200Hz時(shí),引起的誤差為最大范圍的0.55%/g,量程代號2(微差壓)為:±0.25%
電源影響:小于輸出范圍的±0.005%/V
安裝位置:未能垂直安裝時(shí),可能產(chǎn)生小于0.24Kpa的零位誤差.通過零位調(diào)整可消除.量程無影響
結(jié)構(gòu)材料:
隔離膜片:316不銹鋼,哈氏合金C,        蒙乃爾合金
排氣/排液閥: 316不銹鋼,哈氏合金C,        蒙乃爾合金
法蘭和接頭:碳鋼鍍鎳,316不銹鋼,哈氏合金C
接觸介質(zhì)"O"形環(huán): 橡膠,氟橡膠
灌充液:硅油或惰性油
螺栓:碳鋼鍍鎳
殼體材料:低銅鋁合金,表面涂層為環(huán)氧噴塑
引壓連接件:壓力溶蝕連接螺孔為1/4-18NPT,引壓接頭連接螺孔為1/2-14NPT
          中心距詳見外形尺寸圖
電氣連接孔:M20X1.5
重 量:約5Kg(不含附件)
工作原理
1151/3051系列智能電容式壓力變送器檢測部分是一個(gè)可變電容,稱為"δ"室,被測壓力作用在"δ"室兩側(cè)隔離膜片上,通過隔離膜片和"δ"室內(nèi)灌充液傳至中心膜片.中心膜片是具有伸縮性的彈性元件,
與兩側(cè)絕緣體的極板各組成一個(gè)電容,隨著被測壓力的變化中心膜片產(chǎn)生相應(yīng)的位移變化,這種位移變化轉(zhuǎn)變?yōu)殡娙輼O板上的差動電容.改電容量的變化值與被測壓力的變化成正比.通過檢測差動電容的大小,轉(zhuǎn)換為線性的電信號. "δ"室的結(jié)構(gòu)圖如下:
功能參數(shù)
使用對象:液體.氣體和蒸汽
測量范圍:0.5~40000Kpa(詳見型號規(guī)格表)
輸出信號: 4-20mA(可輸出開放信號) 與HART協(xié)議兼容的數(shù)字信號
供電電源:12~45VDC,一般工作電源為24VDV
負(fù)載特性:與供電電源有關(guān)(見圖),負(fù)載阻抗RL與電源電壓VS關(guān)系式:
                 RL≤50(VS-12)
溫度范圍:電子組件:-30~70℃
         灌充硅油:- 30~104℃
         法蘭式或灌充高溫硅油:15~315℃
顯   示:1.智能LCD顯示(顯示器工作溫度-25~70℃)
       2.31/2位LCD(顯示器工作溫度-25~65℃)
       3.指針式表頭(工作溫度-30~80℃)
量程零位:外部連續(xù)可調(diào)
正負(fù)遷移:差壓變送器:最大正遷移為500%,最大負(fù)遷移為600%
         壓力變送器:最大正遷移為500%,最大負(fù)遷移不大于大氣壓
         絕壓變送器:最大正遷移為500%,不可負(fù)遷移
過載壓力:不超過規(guī)定壓力的1.15倍
阻尼時(shí)間:0.2~1.67s可調(diào)
防    爆:隔爆型dⅡBT4  本安型iaⅡCT6
防    護(hù):IP65
技術(shù)參數(shù)
(不帶遷移,標(biāo)準(zhǔn)工作條件下,充硅油,隔離膜片為316L)
精度等級:0.1% 0.25%
穩(wěn)定性:六個(gè)月內(nèi)不超過變送器精度
溫度影響:在最大量程時(shí),每10℃變化見下表
量程代號
精度等級
0.1級
0.25級
1
/
/
2
下限:≤±0.3% 量程≤±0.5%
下限:≤±0.5%  量程≤±1%
3~8
下限:≤±0.15% 量程≤±0.25%
下限:≤±0.25% 量程≤±0.5%
振動影響:任何方向上振動頻率200Hz時(shí),引起的誤差為最大范圍的0.55%/g,量程代號2(微差壓)為:±0.25%
電源影響:小于輸出范圍的±0.005%/V
安裝位置:未能垂直安裝時(shí),可能產(chǎn)生小于0.24Kpa的零位誤差.通過零位調(diào)整可消除.量程無影響
結(jié)構(gòu)材料:
隔離膜片:316不銹鋼,哈氏合金C,        蒙乃爾合金
排氣/排液閥: 316不銹鋼,哈氏合金C,        蒙乃爾合金
法蘭和接頭:碳鋼鍍鎳,316不銹鋼,哈氏合金C
接觸介質(zhì)"O"形環(huán): 橡膠,氟橡膠
灌充液:硅油或惰性油
螺栓:碳鋼鍍鎳
殼體材料:低銅鋁合金,表面涂層為環(huán)氧噴塑
引壓連接件:壓力溶蝕連接螺孔為1/4-18NPT,引壓接頭連接螺孔為1/2-14NPT
          中心距詳見外形尺寸圖
電氣連接孔:M20X1.5
重 量:約5Kg(不含附件)
工作原理
1151/3051系列智能電容式壓力變送器檢測部分是一個(gè)可變電容,稱為"δ"室,被測壓力作用在"δ"室兩側(cè)隔離膜片上,通過隔離膜片和"δ"室內(nèi)灌充液傳至中心膜片.中心膜片是具有伸縮性的彈性元件,
與兩側(cè)絕緣體的極板各組成一個(gè)電容,隨著被測壓力的變化中心膜片產(chǎn)生相應(yīng)的位移變化,這種位移變化轉(zhuǎn)變?yōu)殡娙輼O板上的差動電容.改電容量的變化值與被測壓力的變化成正比.通過檢測差動電容的大小,轉(zhuǎn)換為線性的電信號. "δ"室的結(jié)構(gòu)圖如下:
功能參數(shù)
使用對象:液體.氣體和蒸汽
測量范圍:0.5~40000Kpa(詳見型號規(guī)格表)
輸出信號: 4-20mA(可輸出開放信號) 與HART協(xié)議兼容的數(shù)字信號
供電電源:12~45VDC,一般工作電源為24VDV
負(fù)載特性:與供電電源有關(guān)(見圖),負(fù)載阻抗RL與電源電壓VS關(guān)系式:
                 RL≤50(VS-12)
溫度范圍:電子組件:-30~70℃
         灌充硅油:- 30~104℃
         法蘭式或灌充高溫硅油:15~315℃
顯   示:1.智能LCD顯示(顯示器工作溫度-25~70℃)
       2.31/2位LCD(顯示器工作溫度-25~65℃)
       3.指針式表頭(工作溫度-30~80℃)
量程零位:外部連續(xù)可調(diào)
正負(fù)遷移:差壓變送器:最大正遷移為500%,最大負(fù)遷移為600%
         壓力變送器:最大正遷移為500%,最大負(fù)遷移不大于大氣壓
         絕壓變送器:最大正遷移為500%,不可負(fù)遷移
過載壓力:不超過規(guī)定壓力的1.15倍
阻尼時(shí)間:0.2~1.67s可調(diào)
防    爆:隔爆型dⅡBT4  本安型iaⅡCT6
防    護(hù):IP65
技術(shù)參數(shù)
(不帶遷移,標(biāo)準(zhǔn)工作條件下,充硅油,隔離膜片為316L)
精度等級:0.1% 0.25%
穩(wěn)定性:六個(gè)月內(nèi)不超過變送器精度
溫度影響:在最大量程時(shí),每10℃變化見下表
量程代號
精度等級
0.1級
0.25級
1
/
/
2
下限:≤±0.3% 量程≤±0.5%
下限:≤±0.5%  量程≤±1%
3~8
下限:≤±0.15% 量程≤±0.25%
下限:≤±0.25% 量程≤±0.5%
振動影響:任何方向上振動頻率200Hz時(shí),引起的誤差為最大范圍的0.55%/g,量程代號2(微差壓)為:±0.25%
電源影響:小于輸出范圍的±0.005%/V
安裝位置:未能垂直安裝時(shí),可能產(chǎn)生小于0.24Kpa的零位誤差.通過零位調(diào)整可消除.量程無影響
結(jié)構(gòu)材料:
隔離膜片:316不銹鋼,哈氏合金C,        蒙乃爾合金
排氣/排液閥: 316不銹鋼,哈氏合金C,        蒙乃爾合金
法蘭和接頭:碳鋼鍍鎳,316不銹鋼,哈氏合金C
接觸介質(zhì)"O"形環(huán): 橡膠,氟橡膠
灌充液:硅油或惰性油
螺栓:碳鋼鍍鎳
殼體材料:低銅鋁合金,表面涂層為環(huán)氧噴塑
引壓連接件:壓力溶蝕連接螺孔為1/4-18NPT,引壓接頭連接螺孔為1/2-14NPT
          中心距詳見外形尺寸圖
電氣連接孔:M20X1.5
重 量:約5Kg(不含附件)
工作原理
1151/3051系列智能電容式壓力變送器檢測部分是一個(gè)可變電容,稱為"δ"室,被測壓力作用在"δ"室兩側(cè)隔離膜片上,通過隔離膜片和"δ"室內(nèi)灌充液傳至中心膜片.中心膜片是具有伸縮性的彈性元件,
與兩側(cè)絕緣體的極板各組成一個(gè)電容,隨著被測壓力的變化中心膜片產(chǎn)生相應(yīng)的位移變化,這種位移變化轉(zhuǎn)變?yōu)殡娙輼O板上的差動電容.改電容量的變化值與被測壓力的變化成正比.通過檢測差動電容的大小,轉(zhuǎn)換為線性的電信號. "δ"室的結(jié)構(gòu)圖如下:
功能參數(shù)
使用對象:液體.氣體和蒸汽
測量范圍:0.5~40000Kpa(詳見型號規(guī)格表)
輸出信號: 4-20mA(可輸出開放信號) 與HART協(xié)議兼容的數(shù)字信號
供電電源:12~45VDC,一般工作電源為24VDV
負(fù)載特性:與供電電源有關(guān)(見圖),負(fù)載阻抗RL與電源電壓VS關(guān)系式:
                 RL≤50(VS-12)
溫度范圍:電子組件:-30~70℃
         灌充硅油:- 30~104℃
         法蘭式或灌充高溫硅油:15~315℃
顯   示:1.智能LCD顯示(顯示器工作溫度-25~70℃)
       2.31/2位LCD(顯示器工作溫度-25~65℃)
       3.指針式表頭(工作溫度-30~80℃)
量程零位:外部連續(xù)可調(diào)
正負(fù)遷移:差壓變送器:最大正遷移為500%,最大負(fù)遷移為600%
         壓力變送器:最大正遷移為500%,最大負(fù)遷移不大于大氣壓
         絕壓變送器:最大正遷移為500%,不可負(fù)遷移
過載壓力:不超過規(guī)定壓力的1.15倍
阻尼時(shí)間:0.2~1.67s可調(diào)
防    爆:隔爆型dⅡBT4  本安型iaⅡCT6
防    護(hù):IP65
技術(shù)參數(shù)
(不帶遷移,標(biāo)準(zhǔn)工作條件下,充硅油,隔離膜片為316L)
精度等級:0.1% 0.25%
穩(wěn)定性:六個(gè)月內(nèi)不超過變送器精度
溫度影響:在最大量程時(shí),每10℃變化見下表
量程代號
精度等級
0.1級
0.25級
1
/
/
2
下限:≤±0.3% 量程≤±0.5%
下限:≤±0.5%  量程≤±1%
3~8
下限:≤±0.15% 量程≤±0.25%
下限:≤±0.25% 量程≤±0.5%
振動影響:任何方向上振動頻率200Hz時(shí),引起的誤差為最大范圍的0.55%/g,量程代號2(微差壓)為:±0.25%
電源影響:小于輸出范圍的±0.005%/V
安裝位置:未能垂直安裝時(shí),可能產(chǎn)生小于0.24Kpa的零位誤差.通過零位調(diào)整可消除.量程無影響
結(jié)構(gòu)材料:
隔離膜片:316不銹鋼,哈氏合金C,        蒙乃爾合金
排氣/排液閥: 316不銹鋼,哈氏合金C,        蒙乃爾合金
法蘭和接頭:碳鋼鍍鎳,316不銹鋼,哈氏合金C
接觸介質(zhì)"O"形環(huán): 橡膠,氟橡膠
灌充液:硅油或惰性油
螺栓:碳鋼鍍鎳
殼體材料:低銅鋁合金,表面涂層為環(huán)氧噴塑
引壓連接件:壓力溶蝕連接螺孔為1/4-18NPT,引壓接頭連接螺孔為1/2-14NPT
          中心距詳見外形尺寸圖
電氣連接孔:M20X1.5
重 量:約5Kg(不含附件)

XH1151/3051帶遠(yuǎn)傳型電容式壓力變送器

XH1151/3051帶遠(yuǎn)傳型電容式壓力變送器

為了適應(yīng)不同的安裝需求,本系列變送器具有多種形式的遠(yuǎn)傳裝置供用戶選擇,變送器的主體結(jié)構(gòu)與差壓/壓力變送器相同。  遠(yuǎn)傳變送器主要用于以下場合的測量: 1)被測介質(zhì)對變送器接頭和敏感元件有腐蝕作用時(shí); 2)高溫介質(zhì)需要與變送器隔離時(shí); 3)介質(zhì)含固態(tài)懸浮物或易老化、易結(jié)晶、高粘度易堵塞時(shí); 4)更換被測介質(zhì)需要沖洗而不容易交混時(shí); 5)必須保持衛(wèi)生條件,防止污染時(shí)

FG500FG500型設(shè)備級壓力變送器

FG500型設(shè)備級壓力變送器

一.簡介:         

FG500型設(shè)備級壓力變送器采用的隔離式膜片結(jié)構(gòu)的傳感器和高品質(zhì)的集成電路組裝而成,再配合緊湊的外殼,外殼經(jīng)過密封與外部隔離,能滿足防潮、防水防爆、防塵等惡劣工況要求。組成具有高品低價(jià)位,體積小巧等特點(diǎn)的壓力測量儀表。

FG500可根據(jù)結(jié)構(gòu)和傳感器的不同分為4種型號

     FG501赫斯曼結(jié)構(gòu)(采用擴(kuò)散硅傳感器)

     FG502赫斯曼數(shù)顯結(jié)構(gòu)(采用擴(kuò)散硅傳感器)

     FG503防水接線盒結(jié)構(gòu)。(采用擴(kuò)散硅傳感器)

     FG504衛(wèi)生型防水接線盒結(jié)構(gòu)(采用陶瓷電容傳感受器)

 

二.工作原理

1.?dāng)U散硅傳感器

FG500系列設(shè)備級壓力變送器的核心是一個(gè)擴(kuò)散硅敏感元件,它是在硅基片上采用離子注入并經(jīng)激光修正制成惠斯登電橋,過程壓力作用于傳感器的隔離膜片上使膜片產(chǎn)生位移,通過膜盒內(nèi)的硅油壓力傳遞到硅基片上,同時(shí)參考端的壓力(大氣壓、絕壓或密封壓)作用于硅片的另一測,這樣在硅片的兩邊就加上了一個(gè)差壓,差壓在硅片上產(chǎn)生了一個(gè)應(yīng)力場,使惠斯登電橋的四支電阻,有兩支因拉伸而阻值變小,另外兩支因壓縮而阻值變大,變化量為Δ R,橋臂阻值的變化使電橋失去平衡這樣就產(chǎn)生了一個(gè)與壓力成正比的電壓輸出信號

由于Δ R與施加的壓力成正比,因此:

Vout=k×Vb×P+ V0      

  式中:Vout為輸出電壓;

k為靈敏度系數(shù);

Vb為供橋電壓;

V0為電橋零位輸出;

P為被測壓力

Vout經(jīng)過差分歸一放大器輸出放大后,再經(jīng)過電壓電流的轉(zhuǎn)換,變換成相應(yīng)的電流信號,該電流信號通過非線性矯正環(huán)路的補(bǔ)償,即產(chǎn)生了與輸入壓力成線性對應(yīng)關(guān)系的4-20mA標(biāo)準(zhǔn)信號輸出。

2.陶瓷電容傳感器

介質(zhì)壓力直接作用于陶瓷膜片,使測量膜片產(chǎn)生偏移。正常的壓力使膜片偏移0.025mm,超壓狀態(tài)也只使膜片偏移0.1mm.此時(shí),測量膜片貼到了陶瓷支架上,避免了損壞。膜片位移產(chǎn)生的電容量,由與其直接連接的電子部件檢測,放大和轉(zhuǎn)換為標(biāo)準(zhǔn)信號輸出。

 

三.技術(shù)參數(shù):

供電電壓:13~36VDC               

輸出信號:4~20mA(二線制)

負(fù)載電阻:R≤(U-13)/20-r(Ω)U電源r;線阻功耗;2mW

連接電纜:屏蔽電纜

綜合精度:0.25%F.S

穩(wěn)定性:0.2%

零點(diǎn)溫源:≤0.15%/10℃

響應(yīng)時(shí)間:<0.1S

電源影響:0.005%/V

介質(zhì)溫度:-20~80℃

環(huán)境溫度:-30~50℃

相應(yīng)濕度:≤95%

外殼:不銹鋼,防護(hù)等級IP65

電器接口材質(zhì):赫斯曼,ABS

過程接口材質(zhì):不銹鋼

 

四.接線

    FG500為標(biāo)準(zhǔn)2線制儀表,電源(信號)端子位于儀表殼體內(nèi)的接線側(cè),電源是通過信號線送到變送器的,不需要附加線。信號線應(yīng)使用屏蔽線或兩根紐在一起的雙絞線,盡量不要與其它電源線一起通過線管或明線槽,也不可在大功率設(shè)備附近穿過。

儀表殼體上有接線孔,應(yīng)當(dāng)用密封件密封,以防儀表殼內(nèi)進(jìn)水,信號線可以浮空或在信號回路中任何一點(diǎn)接地,變送器的外殼可以接地也可不接地,為使安裝的變送器保持正常工作,必須注意下述事項(xiàng):

(1)蓋子蓋必須用力擰緊,但不得損壞螺紋;

(2)過渡連接件必須擰緊;

(3)接線孔必須用密封件密封;

1、旋開中央的小螺釘,拔下壓力變送器的接線端子塊。

2、取下外面的橡膠套,然后用小螺絲刀從“shift”所指的方形孔撬出接線端這就可以看到壓力變送器的四個(gè)接線端子。

3、松開外殼上的引線孔塞,把纜線從孔中央穿入“1”接電源的“+24V”,“2”接源的“-24V”。

4、 確認(rèn)接線沒有錯(cuò)誤,把接線端子推入殼體內(nèi),擰緊引線孔塞,安上外面的橡膠套,把接線端子插入壓力變送器,擰緊小螺釘。

1、旋下變送器端蓋。

2、兩根連接導(dǎo)線從殼體側(cè)面引線穿入,一根連接變送器正極端子與電源

 正極;另一根連接變送器負(fù)極端子與穩(wěn)壓電源負(fù)極(中間可串接負(fù)載)。

3、黃色為接地線.如變送器外殼已接地,則黃線不用接.

4、旋緊鎖緊塞。

5.旋緊變送器端蓋。

 

五.過程連接尺寸圖

FG500設(shè)備級壓力變送器過程連接的基本型為兩種見圖(1.4)該變送器除兩種基本型過程連接件M20×15和1/2”NPT外螺紋外,還可以根據(jù)用戶的現(xiàn)場需要設(shè)計(jì)各種便于安裝和測量不同介質(zhì)的過程連接件,比如需要測量地下管道或高空管道或安裝位置陜窄的場合,為了便于維護(hù)工人的維護(hù)保養(yǎng)可以將傳感器和儀表主體分開用屏蔽軟線連接,非常方便操作工人的維護(hù),又如需要測量高粘度、高溫、食品、藥品的介質(zhì)時(shí)我們加裝帶隔離膜片的過程連接件,滿足了這些場合的使用,特殊的使用場合由我公司技術(shù)人員現(xiàn)場提供咨詢服務(wù)。

 

六.安裝

a)使用FG500壓力變送器對壓力進(jìn)行測量,很大程度上取決于變送器的正確安裝,在露天使用環(huán)境比較惡劣,然而變送器應(yīng)盡量安裝在溫度梯度和溫度波動比較小的地方,同時(shí)要避免振動和沖擊.典型安裝有管裝和板裝兩種,

b)FG500壓力變送器,可直接安裝在測量點(diǎn)上,連接螺紋:1/2NPT或者M(jìn)20×1.5,為確保變送器接頭的密封,應(yīng)先在接頭外卷上密封膠帶,然后擰緊變送器.

c) 變送器相對流程管道的正確安裝取決于被測介質(zhì),考慮到下面幾種情況可決定的安裝形式。

· 強(qiáng)腐蝕性的或過熱的介質(zhì)不應(yīng)與變送器直接接觸。

·防止渣子在引壓管內(nèi)沉淀,堵塞管路。

·應(yīng)盡可能縮短引壓管,減少誤差。

·引壓管應(yīng)裝在溫度梯度和溫度波動小的地方。

在測量蒸汽或其它高溫介質(zhì)時(shí),必須加裝冷凝圈 ,用于蒸汽測量時(shí)冷凝圈內(nèi)充滿冷水,以防變送器與蒸汽直接接觸,必要時(shí)可加裝冷凝罐。

變送器與測量介質(zhì)連接管路是為把取壓口介質(zhì)壓力輸?shù)阶兯推?,在壓力傳輸中引起誤差的主要原因?yàn)椋海?)泄漏;(2)摩擦損失(特別使用噴吹系統(tǒng)時(shí)); (3)液體管路集氣體;(4)氣體管路集液體。

solution S500solution S500設(shè)備級壓力變送器

solution S500設(shè)備級壓力變送器

 

 
產(chǎn)品描述:

S500 系列壓力變送器是全不銹鋼焊接結(jié)構(gòu),零點(diǎn)量程現(xiàn)場可調(diào)。S500 設(shè)計(jì)出發(fā)點(diǎn)主要考慮的是應(yīng)用 在需要嚴(yán)格控制安裝空間的場合,例如一些工業(yè)設(shè)備試驗(yàn)臺,生產(chǎn)模擬裝置。

技術(shù)參數(shù):

技術(shù)參數(shù) 量程 -100KPa~150MPa 供電電壓 18~36VDC 輸出信號 4~20mA(兩線制) 1~5V(三線制) 負(fù)載電阻≤ 1000 Ω 功耗 2mW 連接電纜屏蔽電纜 精度等級0.1、0.25、0.5 級 介質(zhì)溫度A:-40~85℃ B:-40~125℃ 環(huán)境溫度-40~85℃(60℃以上需聲明) 耐振≤ 30HZ/1mm 過載2~3 倍

應(yīng)用范圍:

石油、化工、紡織、冶金、礦山、輕工、醫(yī)藥、電力、環(huán)保、市政、食品和科研領(lǐng)域等

 

CPT2500WIKA CPT2500 CPA2500 壓力變送器 帶USB接口 帶配置評估軟件

接口尺寸: 1/2(mm) 加工定制:
防護(hù)等級: IP65 測量范圍: 0-1000BAR(kPa)
類型: WIKA 帶USB接口的壓力變送器 CPT2500 CPA2500 帶軟件 壓力變送器 防爆等級: IP65
型號: CPT2500 CPA2500 測量介質(zhì): 液體 氣體
精度等級: 0.2 品牌: WIKA/威卡
輸出信號: 4-20(mA) 電源電壓: 10-30(V)

 

WIKA 帶USB接口的壓力變送器 CPT2500 CPA2500 帶軟件 壓力變送器

Pressure transmitter model CPT2500with USB adapter CPA2500 and software USBsoft2500

Calibration technology

USB pressure transmitter model CPT2500with model CPA2500 USB adapter and USBsoft2500 software

Model CPT2500 USB pressure transmitter with model CPA2500 USB adapter

 

   Applications 

    Calibration service companies and service industry    Quality assurance    Recording and monitoring of pressure processes

   Special features

    Recording interval CAN be set from 1 ms ... 10 s    Measuring ranges from 0 ... 100 mbar to 0 ... 1,000 bar    Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate)    No external voltage supply required    USBsoft2500 software for configuration, and the recording and analysis of measured values

 

   Description

    The CPT2500 USB pressure transmitter is suitable for connection to any PC with a USB port, via the CPA2500 USB adapter.

    For the USB adapter there are stainless steel pressure transmitters available with measuring ranges up to 1,000 bar. The USB adapter automatically detects the measuring range of the currently connected pressure transmitter and ensures ahighly accurate pressure measurement.

    The USBsoft2500 software is delivered as standard with the USB adapter. With it, all settings for recording the pressure process can be made. The recorded measured values can be graphically displayed and evaluated.

    The interval for recording can be set in the range of 1 ms ... 10 s. With a recording interval of more than 5 ms the following data is recorded in addition to the current measured

 

   value:    the mean value over the recording interval.    the maximum and minimum value during the recording interval.

    Thus pressure peaks within the overall recording interval can be very easily identified.    It is also possible to set start and stop conditions for the recording. In this way it is possible to detect pressure peaks with a resolution of up to 1 ms.

    The CPT2500 is a thus very well suited to all applications where, over a limited timespan, pressure processes must be recorded and analysed with high resolution.    For easy transport and safe storage, the USB adapter is delivered in a compact transport case, which can also hold one or more pressure transmitters.

 

    Dimensions in mm

 

    Specifications Model CPT2500   USBsoft2500 configuration and evaluation software 

    The USBsoft2500 software is required for the operation of the model CPT2500 USB pressure transmitter in connection with the model CPA2500 USB adapter. This enables the configuration of the pressure transmitter as well as the selection of the various recording settings. 

    The software also allows different start/stop conditions to be defined, in order to easily identify, for example, a single pressure peak. 

    Graphical evaluation of the measured data (including mean, min- and max-values), in addition the measured data can also be exported to other software.    Several series of measurements can be displayed in a single chart.

 

   System requirements    CPU with 1 GHz    At least 20 MB free hard disc space    CD-ROM drive    256 MB RAM    Microsoft® Windows® 98 SE, 2000, XP, Vista or Windows® 7    Mouse    One free USB port 

   Performance data    Recording interval of 1 ms ... 10 s    Data export to other programs e.g. Excel®    Languages: German/English/Spanish/Czech

 

    Scope of delivery     USB pressure transmitter model CPT2500     USB adapter model CPA2500     Software USBsoft2500     Transport case     Operating instructions     3.1 calibration certificate per DIN EN 10204

    Options     DKD/DAkkS certified accuracy of 0.2 % or 0.1 %

   Accessories     Various pressure adapters     "Minimess" quick-connect process connection system     Additional pressure sensors

Ordering information Model / Unit / Measuring range / Accuracy / Process connection / Extension cable / Type of certificate / Accessories / Additional order information

 

歡迎致電咨詢訂購WIKA 帶USB接口的壓力變送器 CPT2500 CPA2500 帶軟件 壓力變送器

電話: 56291930 15910733293

傳真:

QQ:823377546 1491421115 2636968574

郵箱:sales@zoriver.cn

公司官網(wǎng):http://www.zoriver.cn    http://www.zoriver.com.cn

該公司產(chǎn)品分類: WIKA壓力及溫度儀表 瑞士TRAFAG壓力及溫度儀表

JPDS4000壓力變送器,工業(yè)級壓力變送器,一體化壓力變送器,高精度壓力變送器

 壓力變送器壓力敏感核心采用了高性能的硅壓阻式壓力充油芯體,內(nèi)部的專用集成電路將傳感器毫伏信號轉(zhuǎn)換成標(biāo)準(zhǔn)遠(yuǎn)距離的傳輸電流信號,可以直接與計(jì)算機(jī)接口卡、控制儀表、智能儀表或PLC等方便相連。該系列產(chǎn)品廣泛應(yīng)用于工業(yè)過程控制、石油、化工、冶金等行業(yè)。

1 主要技術(shù)參數(shù)

⑴ 工作溫度:-20℃~80℃;

⑵ 變送器的準(zhǔn)確度等級分為:

0.1級,基本誤差為±0.1;

0.3級,基本誤差為±0.3;

0.5級,基本誤差為±0.5(基本誤差以量程的百分?jǐn)?shù)表示)。

⑶ 熱零點(diǎn)漂移

環(huán)境溫度偏離參比工作條件時(shí),變送器的零點(diǎn)漂移應(yīng)不大于0.03%FS/℃。

⑷ 熱靈敏度漂移

環(huán)境溫度偏離參比工作條件時(shí),變送器的滿量程漂移應(yīng)不大于0.03%FS/℃。

⑸ 絕緣電阻

在參比工作條件下,變送器各端子對地之間的絕緣電阻不得低于50MΩ/250V

2 外形及安裝

     外形結(jié)構(gòu)見圖1,該壓力變送器由殼體,

放大器,接線端子組成,根據(jù)用戶的需要

可以選用指針表,液晶表頭顯示。

 

 

 

 

 

 

 

 

 

 

1

 

3 安裝方法                                  

    ⑴ 選擇易于操作、維護(hù)的地方進(jìn)行安裝;

⑵ 應(yīng)盡量遠(yuǎn)離振動源安裝;

⑶ 應(yīng)盡量遠(yuǎn)離熱源的地方安裝;

⑷ 直接安裝在管道或設(shè)備上,安裝時(shí)用扳手夾緊在變送器六方處。

 

 

4 電氣連接

打開儀表蓋(接線端子面),見接線端子,電源連接見圖2  

 

 

 

 

 

 

 

 

 

 

 

 

                               2

5 零點(diǎn),增益調(diào)節(jié)

零點(diǎn)及增益的調(diào)整方法:

壓力表在出廠前,已經(jīng)過標(biāo)定,無須用戶再次調(diào)整。若在使用過程中發(fā)生零位和滿量程偏離,規(guī)定每年校檢,可以在高一級精度的壓力源上重新標(biāo)定。方法如下:

在無壓力的情況下,調(diào)整調(diào)零Z電位器,使電流輸出為4.000mA。加滿量程壓力,調(diào)整增益S電位器,使電流輸出為20.000mA。如此反復(fù)多次,最終使壓力表的零位和滿量程調(diào)整到標(biāo)準(zhǔn)值。

6 安全使用注意事項(xiàng)

⑴ 搬運(yùn)與安裝變送器時(shí)應(yīng)小心謹(jǐn)慎,避免碰撞而影響電路的性能。

⑵ 變送器進(jìn)壓口內(nèi)有隔離膜片,切勿人為用異物觸碰。

⑶ 變送器外螺紋處一定要注意密封,否則會造成壓力不準(zhǔn)不穩(wěn)。

⑷ 安全柵須取得防爆合格證,其安裝應(yīng)按其說明書的要求進(jìn)行。

⑸ 在產(chǎn)品安裝使用中如遇到問題請與我公司聯(lián)系,在產(chǎn)品發(fā)生異常時(shí),請不要擅自打開進(jìn)行修理,應(yīng)及時(shí)與廠家聯(lián)系。

 

該公司產(chǎn)品分類: 浮子流量計(jì) 上海覺沛 汽包水位傳感器 溫度傳感器 液位變送器 壓力儀表 超聲波液位計(jì) 渦輪流量計(jì)

FG500FG500型設(shè)備級壓力變送器

FG500型設(shè)備級壓力變送器

一.簡介:         

FG500型設(shè)備級壓力變送器采用的隔離式膜片結(jié)構(gòu)的傳感器和高品質(zhì)的集成電路組裝而成,再配合緊湊的外殼,外殼經(jīng)過密封與外部隔離,能滿足防潮、防水防爆、防塵等惡劣工況要求。組成具有高品低價(jià)位,體積小巧等特點(diǎn)的壓力測量儀表。

FG500可根據(jù)結(jié)構(gòu)和傳感器的不同分為4種型號

     FG501赫斯曼結(jié)構(gòu)(采用擴(kuò)散硅傳感器)

     FG502赫斯曼數(shù)顯結(jié)構(gòu)(采用擴(kuò)散硅傳感器)

     FG503防水接線盒結(jié)構(gòu)。(采用擴(kuò)散硅傳感器)

     FG504衛(wèi)生型防水接線盒結(jié)構(gòu)(采用陶瓷電容傳感受器)

 

二.工作原理

1.?dāng)U散硅傳感器

FG500系列設(shè)備級壓力變送器的核心是一個(gè)擴(kuò)散硅敏感元件,它是在硅基片上采用離子注入并經(jīng)激光修正制成惠斯登電橋,過程壓力作用于傳感器的隔離膜片上使膜片產(chǎn)生位移,通過膜盒內(nèi)的硅油壓力傳遞到硅基片上,同時(shí)參考端的壓力(大氣壓、絕壓或密封壓)作用于硅片的另一測,這樣在硅片的兩邊就加上了一個(gè)差壓,差壓在硅片上產(chǎn)生了一個(gè)應(yīng)力場,使惠斯登電橋的四支電阻,有兩支因拉伸而阻值變小,另外兩支因壓縮而阻值變大,變化量為Δ R,橋臂阻值的變化使電橋失去平衡這樣就產(chǎn)生了一個(gè)與壓力成正比的電壓輸出信號

由于Δ R與施加的壓力成正比,因此:

Vout=k×Vb×P+ V0      

  式中:Vout為輸出電壓;

k為靈敏度系數(shù);

Vb為供橋電壓;

V0為電橋零位輸出;

P為被測壓力

Vout經(jīng)過差分歸一放大器輸出放大后,再經(jīng)過電壓電流的轉(zhuǎn)換,變換成相應(yīng)的電流信號,該電流信號通過非線性矯正環(huán)路的補(bǔ)償,即產(chǎn)生了與輸入壓力成線性對應(yīng)關(guān)系的4-20mA標(biāo)準(zhǔn)信號輸出。

2.陶瓷電容傳感器

介質(zhì)壓力直接作用于陶瓷膜片,使測量膜片產(chǎn)生偏移。正常的壓力使膜片偏移0.025mm,超壓狀態(tài)也只使膜片偏移0.1mm.此時(shí),測量膜片貼到了陶瓷支架上,避免了損壞。膜片位移產(chǎn)生的電容量,由與其直接連接的電子部件檢測,放大和轉(zhuǎn)換為標(biāo)準(zhǔn)信號輸出。

 

三.技術(shù)參數(shù):

供電電壓:13~36VDC               

輸出信號:4~20mA(二線制)

負(fù)載電阻:R≤(U-13)/20-r(Ω)U電源r;線阻功耗;2mW

連接電纜:屏蔽電纜

綜合精度:0.25%F.S

穩(wěn)定性:0.2%

零點(diǎn)溫源:≤0.15%/10℃

響應(yīng)時(shí)間:<0.1S

電源影響:0.005%/V

介質(zhì)溫度:-20~80℃

環(huán)境溫度:-30~50℃

相應(yīng)濕度:≤95%

外殼:不銹鋼,防護(hù)等級IP65

電器接口材質(zhì):赫斯曼,ABS

過程接口材質(zhì):不銹鋼

 

四.接線

    FG500為標(biāo)準(zhǔn)2線制儀表,電源(信號)端子位于儀表殼體內(nèi)的接線側(cè),電源是通過信號線送到變送器的,不需要附加線。信號線應(yīng)使用屏蔽線或兩根紐在一起的雙絞線,盡量不要與其它電源線一起通過線管或明線槽,也不可在大功率設(shè)備附近穿過。

儀表殼體上有接線孔,應(yīng)當(dāng)用密封件密封,以防儀表殼內(nèi)進(jìn)水,信號線可以浮空或在信號回路中任何一點(diǎn)接地,變送器的外殼可以接地也可不接地,為使安裝的變送器保持正常工作,必須注意下述事項(xiàng):

(1)蓋子蓋必須用力擰緊,但不得損壞螺紋;

(2)過渡連接件必須擰緊;

(3)接線孔必須用密封件密封;

1、旋開中央的小螺釘,拔下壓力變送器的接線端子塊。

2、取下外面的橡膠套,然后用小螺絲刀從“shift”所指的方形孔撬出接線端這就可以看到壓力變送器的四個(gè)接線端子。

3、松開外殼上的引線孔塞,把纜線從孔中央穿入“1”接電源的“+24V”,“2”接源的“-24V”。

4、 確認(rèn)接線沒有錯(cuò)誤,把接線端子推入殼體內(nèi),擰緊引線孔塞,安上外面的橡膠套,把接線端子插入壓力變送器,擰緊小螺釘。

1、旋下變送器端蓋。

2、兩根連接導(dǎo)線從殼體側(cè)面引線穿入,一根連接變送器正極端子與電源

 正極;另一根連接變送器負(fù)極端子與穩(wěn)壓電源負(fù)極(中間可串接負(fù)載)。

3、黃色為接地線.如變送器外殼已接地,則黃線不用接.

4、旋緊鎖緊塞。

5.旋緊變送器端蓋。

 

五.過程連接尺寸圖

FG500設(shè)備級壓力變送器過程連接的基本型為兩種見圖(1.4)該變送器除兩種基本型過程連接件M20×15和1/2”NPT外螺紋外,還可以根據(jù)用戶的現(xiàn)場需要設(shè)計(jì)各種便于安裝和測量不同介質(zhì)的過程連接件,比如需要測量地下管道或高空管道或安裝位置陜窄的場合,為了便于維護(hù)工人的維護(hù)保養(yǎng)可以將傳感器和儀表主體分開用屏蔽軟線連接,非常方便操作工人的維護(hù),又如需要測量高粘度、高溫、食品、藥品的介質(zhì)時(shí)我們加裝帶隔離膜片的過程連接件,滿足了這些場合的使用,特殊的使用場合由我公司技術(shù)人員現(xiàn)場提供咨詢服務(wù)。

 

六.安裝

a)使用FG500壓力變送器對壓力進(jìn)行測量,很大程度上取決于變送器的正確安裝,在露天使用環(huán)境比較惡劣,然而變送器應(yīng)盡量安裝在溫度梯度和溫度波動比較小的地方,同時(shí)要避免振動和沖擊.典型安裝有管裝和板裝兩種,

b)FG500壓力變送器,可直接安裝在測量點(diǎn)上,連接螺紋:1/2NPT或者M(jìn)20×1.5,為確保變送器接頭的密封,應(yīng)先在接頭外卷上密封膠帶,然后擰緊變送器.

c) 變送器相對流程管道的正確安裝取決于被測介質(zhì),考慮到下面幾種情況可決定的安裝形式。

· 強(qiáng)腐蝕性的或過熱的介質(zhì)不應(yīng)與變送器直接接觸。

·防止渣子在引壓管內(nèi)沉淀,堵塞管路。

·應(yīng)盡可能縮短引壓管,減少誤差。

·引壓管應(yīng)裝在溫度梯度和溫度波動小的地方。

在測量蒸汽或其它高溫介質(zhì)時(shí),必須加裝冷凝圈 ,用于蒸汽測量時(shí)冷凝圈內(nèi)充滿冷水,以防變送器與蒸汽直接接觸,必要時(shí)可加裝冷凝罐。

變送器與測量介質(zhì)連接管路是為把取壓口介質(zhì)壓力輸?shù)阶兯推?,在壓力傳輸中引起誤差的主要原因?yàn)椋海?)泄漏;(2)摩擦損失(特別使用噴吹系統(tǒng)時(shí)); (3)液體管路集氣體;(4)氣體管路集液體。

智能壓力變送器 (CYB-1系列)

     點(diǎn)

精度高:優(yōu)于0.1%FS

穩(wěn)定性好:溫度漂移≤0.005%FS/ 穩(wěn)定性≤0.1%FS/

抗電磁干擾設(shè)計(jì),適合惡劣使用環(huán)境

輸出420mA模擬信號與HART數(shù)字信號

控制點(diǎn)可用按鍵設(shè)定

兼容防浪涌電壓,極性反向保護(hù)

防腐性強(qiáng):316L金屬膜片

本安防爆

技術(shù)參數(shù)

量程

KPa

05、100、500、800、1000

MPa

02、10……100

壓力形式

表壓、絕壓

輸出信號(mA)

420二線制

顯示方式

4LED

精度度等級

0.1

0.2

0.3

非線性

遲滯性(%FS

重復(fù)性

≤0.1

≤0.2

≤0.3

零點(diǎn)漂移(%FS/4h)

≤0.05

≤0.1

≤0.2

零點(diǎn)及靈敏度溫度漂移(%FS/

≤0.005

≤0.01

≤0.02

長期穩(wěn)定性(%FS/年)

≤0.1≤0.2

阻尼(秒)

O32可調(diào)

工作電壓(V)

+12+36(標(biāo)定值為+24)

工作溫度(

-20+85

過載能力(%)

300

壽命

lx108次壓力循環(huán)(25

負(fù)載電阻(Ω)

R=(U-12.5)/0.02-Rd其中:U為電源電壓,Rd為電纜內(nèi)阻

響應(yīng)時(shí)間(1090%)ms

≤1

測量介質(zhì)

316兼容的腐蝕性介質(zhì)

膜片材料

316L不銹鋼

殼體材料

ICr18Ni9Ti和鋁合金

接口

M20xl.5或用戶自定

防爆等級

ExiaII CT6

防護(hù)等級

IP67

 

該公司產(chǎn)品分類: 溫度系列 稱重系列 物位系列 壓力系列 流量系列

超高壓壓力傳感器,超高壓壓力變送器,超高壓傳感器,超高壓變送器

PTP702超高壓壓力傳感器,超高壓壓力變送器,超高壓傳感器,超高壓變送器彈性體采用特殊進(jìn)口材質(zhì)、線切割機(jī)加工藝,一體化結(jié)構(gòu)設(shè)計(jì),適用于大型液壓設(shè)備等的壓力測量與控制。

量 程: 0~150~450(MPa)  綜合精度: 0.2%FS、0.5%FS、1.0%FS 輸出信號: 4~20mA(二線制)、0~5V、1~5V、0~10V(三線制) 供電電壓: 24DCV(9~36DCV) 介質(zhì)溫度: -20~85℃ 環(huán)境溫度: 常溫(-20~85℃) 負(fù)載電阻: 電流輸出型:最大800Ω;電壓輸出型:大于50KΩ 絕緣電阻: 大于2000MΩ (100VDC 密封等級; IP65 穩(wěn)定性能: 0.1%FS/年 振動影響: 在機(jī)械振動頻率20Hz~1000Hz內(nèi),輸出變化小于0.1%FS 電氣接口(信號接口): 四芯屏蔽線、四芯航空接插件、緊線螺母 機(jī)械連接(螺紋接口): M20×1.5、M22×1.5等,其它螺紋可依據(jù)客戶要求設(shè)計(jì)

YB20系列壓力變送器

YB20系列壓力變送器

產(chǎn)品描述:

一、特點(diǎn)
  ☆高精度0.1%FS   ☆高穩(wěn)定性O(shè).3%FS/年   ☆高靈敏度0.05%FS
  ☆具有反向保護(hù)能力、抗干擾能力強(qiáng)、防雷擊、防震、防腐、防潮、耐腐蝕
  ☆結(jié)構(gòu)簡單、體積小、重量輕安裝方便、維修量小   ☆高性能價(jià)格比’
二、概述
    YB20系列壓力變送器采用美國LUCASNOVA公司生產(chǎn)的敏感組件和專用微處理電路組裝。陶瓷傳感器及陶瓷電容傳感器均采用E+H生產(chǎn)的帶溫度自動補(bǔ)償?shù)膫鞲衅髋c美國生產(chǎn)的微處理器組裝。
    YB20系列微差壓傳感器系選用美國SENSORNOVA公司非隔離型擴(kuò)散硅差壓傳感器組件,通過精密溫度補(bǔ)償及獨(dú)特的傳感器應(yīng)力隔離技術(shù)組裝而成,具有測量范圍寬、體積小巧、穩(wěn)定性好、高性等特點(diǎn),特別適用于低量程微差壓測量。如工業(yè)過程風(fēng)壓及流速測量、空氣調(diào)節(jié)及凈化設(shè)備、煙塵治理及環(huán)境保護(hù),爐膛壓力或爐膛負(fù)壓、風(fēng)機(jī)測量及檢漏設(shè)備。儀表符合GB3836.4—83《爆炸性環(huán)境用防爆電器設(shè)備,本質(zhì)安全型電路和電氣設(shè)備“1"》有關(guān)規(guī)定,并取得國家防爆檢驗(yàn)單位頒發(fā)的產(chǎn)品防爆合格證書。
該儀表廣泛用于各行業(yè)容器和管道壓力的測量。
三、主要技術(shù)指標(biāo):
1、被測介質(zhì):液體、氣體、蒸汽
2、測量范圍:0~20mm H2O至 0~6O MPa
3、供電電源及負(fù)載能力:14~36VDC,負(fù)載O~1kΩ本安型24V經(jīng)安全柵盒供電
4、量程調(diào)節(jié):極限量程5:1
5、零點(diǎn)調(diào)節(jié)范圍:為量程的3 0%    .、
6、量程和零位穩(wěn)定性≤±0 .3%FS/年
7、工作介質(zhì)溫度:一400C~1250C
8、環(huán)境條件:A、大氣壓:86~106kPaB、相對濕度:95%C、環(huán)境溫度:一4 00C~6 00C
9、過載能力:滿量程壓力的2倍。差壓:滿量程壓力的5倍
10、材質(zhì):隔離膜片:316SS、陶瓷、哈氏合金膜片、鉑金膜片
     主體連接件:1Cr18Ni9Ti或者316SS
     變送器外殼:鋁合金表面噴涂塑料,塑料,1Crl8Ni9Ti
11、防爆標(biāo)志:TaIICT5,二線輸出4~20mA,24VDC供電,
12、外殼防護(hù)等級:1P65
四、工作原理
    被測壓力通過膜片和硅油傳送到擴(kuò)散硅片上,由于壓阻效應(yīng),四個(gè)橋臂電阻發(fā)生變化,電橋失去平衡,輸出一個(gè)與壓力成正比例的m V電信號,經(jīng)專用微處理電路放本輸出4~20 mA或0~1omA或0~20mA:微處理電路同時(shí)供給電橋一個(gè)極為穩(wěn)定的恒流電流,使輸出信號穩(wěn)定。其原理方塊圖如下。
                          傳感器———一專用電路卜———一4~2 0ma
五、安裝與接線.
  1、安裝.
    A、安裝方式:可直接安裝在測量點(diǎn)上,亦可采用引壓管方式安裝,但引壓管盡可能短一些。
    B、用于蒸汽測量時(shí),引壓管要充滿水,以防傳感器與蒸汽直接接觸。
    C、為儀表高精度、高穩(wěn)定性工作,在壓力傳輸中不應(yīng)有
    (1)泄漏、  (2)摩擦損失(特別是噴吹系統(tǒng))、  (3)液體管路積氣體、
    (4)氣路管路積液體等現(xiàn)象
    D、在測量蒸汽或其它高溫介質(zhì)時(shí),不應(yīng)使變送器工作溫度超過極限值。
    E、測量氣體介質(zhì)壓力,儀表應(yīng)安裝在容器頂端或管路上方。
    F、測量液體介質(zhì)壓力,儀表應(yīng)安裝在容器和管路側(cè)端。
    G、采用引管安裝方式時(shí),測液體介質(zhì)應(yīng)考慮測壓點(diǎn)與儀表之間高度差引起的壓力遷移。
  2、接線
    Y B 2 0系列二線制防爆式壓力變送器接線圖。

六、選型譜表

YB20 
壓力變送器
系列號
 
 1
普通型
類別
 
 2
智能型
 
 1
24VCD
供電方式
 
 2
220V、AC(須配數(shù)字顯示儀表帶24VDC輸出)
 
 1
1/4NPT
安裝方式
 
 2
M20×1.5螺紋連接
 
 3
其它
 
 1
0.1級
精度等級
 
 2
0.2級
 
 3
0.3級
 
 1
擴(kuò)散硅316膜片
傳感器材料
 
 2
陶瓷薄膜
 
 3
陶瓷電容
 
 1
4-20MA輸出
輸出方式
 
 2
4-20MA輸出帶485通訊
 
 3
4-20MA輸出帶HART通訊
 
 4
其它
 
 1
現(xiàn)場無顯示
     現(xiàn)場顯示
 
 2
指針式0-100%現(xiàn)場顯示
 
 3
LCD數(shù)顯示0-100%現(xiàn)場顯示
 
 4
LCD測量值現(xiàn)場顯示
 
 1
表壓
壓力形式
 
 2
絕壓
 
 3
差壓
 
 1
無防爆要求
     防爆要求
 
 2
本安防爆

YB20—
 
 
 
 
 
 
 
 
 
壓力范圍P=
例:YB20-11231111   P=0-0.4MPa表示:通用型壓力變送器,24VDC供電,M20×1.5螺紋連接,擴(kuò)散硅316膜化,表壓,壓力范圍0-0.4MPa。