ZX3351AP型絕對壓力變送器,可以實現(xiàn)對除氣系統(tǒng),蒸餾塔、蒸發(fā)器和結(jié)晶器等的絕對壓力測量,允許在10MPa下的過壓。
使用對象:液體、氣體和蒸氣。
| ZX3351 AP型 | 絕對壓力變送器 | |||||||
|
|
|
| ||||||
| 4 | 0-6~40KPa | |||||||
| 5 | 0-40~250KPa | |||||||
| 6 | 0-0.16~1MPa | |||||||
| 7 | 0-0.4~2.5MPa | |||||||
| 8 | 0-1.6~10MPa | |||||||
|
| 代號 | 功能 | ||||||
| N | 普通模擬型:(輸出:4~20mA) | |||||||
| G | 常規(guī)智能型:(輸出:4~20mA) | |||||||
| S | 標(biāo)準(zhǔn)智能型:(輸出:4~20mA帶HART總線協(xié)議) | |||||||
| Z | 數(shù)字化智能型:(輸出:4~20mA全數(shù)字化傳感器,自帶通訊鍵盤) | |||||||
|
| 代號 | 結(jié)構(gòu)材料 | ||||||
| 法蘭接頭 | 排氣/排液閥 | 隔離膜片 | 灌充液體 | |||||
| J1 | 316不銹鋼 | 316不銹鋼 | 316不銹鋼 | 硅油 | ||||
| J2 | 316不銹鋼 | 316不銹鋼 | 哈氏C-276 | |||||
| J3 | 316不銹鋼 | 316不銹鋼 | 蒙乃爾 | |||||
| J4 | 316不銹鋼 | 316不銹鋼 | 鉭 | |||||
|
| ||||||||
|
| 代號 | 精度 | ||||||
| Q1 | 0.2%FS | |||||||
| Q2 | 0.5%FS | |||||||
|
| 代號 | 電氣連接接頭 | ||||||
| L1 | M20X1.5內(nèi)螺紋 | |||||||
| L2 | 1/2NPT內(nèi)螺紋 | |||||||
|
| 代號 | 附加選項 | ||||||
| M1 | 0~100%線性指示表頭 | |||||||
| M3 | 數(shù)字顯示表頭 | |||||||
| B | 萬能安裝支架 | |||||||
| D0 | 泄放閥在壓力室中部 | |||||||
| D1 | 側(cè)面泄放閥在壓力室上部 | |||||||
| D2 | 側(cè)面泄放閥在壓力室下部 | |||||||
| C0 | 1/2〃錐管內(nèi)螺紋接頭 | |||||||
| C1 | 1/2〃引壓接頭及后部焊接引壓管φ14(供貨時含C0) | |||||||
| C2 | 丁字形螺紋接頭M20X1.5 | |||||||
| d | 防爆型EXdIICT5 | |||||||
| I | 本安型EXiaIICT6 | |||||||
|
| ||||||||
| ZX3351AP 3 N JI Q1 L1 M1BC0 ← 選型舉例 |
定貨須知
1)變送器型號可根據(jù)選型規(guī)格表按需要確定。
2)選型規(guī)格表中的數(shù)字、符號必須填寫清楚、無誤。
3)如有正負(fù)遷移,必須注明遷移量數(shù)值。
4)差壓變送器如需配三閥組,需另行注明。
5)接觸介質(zhì)O形密封環(huán)的材料有橡膠和氟橡膠等。
6)無特殊注明,出廠時灌充液為硅油
阿儀推薦YAW-300C全自動抗折抗壓試驗機
該款設(shè)備是在電液式的基礎(chǔ)上升級的一款微機控制壓力試驗機。產(chǎn)品采用雙工位的試驗空間,具有一機兩用,節(jié)省空間,操作簡單。
產(chǎn)品包裝:木箱 供貨總數(shù):100臺 生產(chǎn)廠家:濟南時光試驗儀器有限公司
壓力試驗機在日常使用中應(yīng)該注意哪些細節(jié)問題呢? 首先,壓力試驗機上的所有附件零部件在不用時應(yīng)該涂防銹油,放于干燥的地方,注意保持清潔衛(wèi)生。 第二,壓力試驗機試驗用油根據(jù)試驗地區(qū)和氣候的不同而存在一些細微的差異,在實驗過程中應(yīng)該時刻關(guān)注油量的多少,發(fā)現(xiàn)不足及時補充。若發(fā)現(xiàn)油用的過快應(yīng)該仔細檢查是否存在漏油點。如果發(fā)現(xiàn)漏油的地方,需檢查試驗機漏油處在哪,各部分螺絲帽、特別是油管接頭處螺母是否擰緊。 第三,實驗之前要注意檢查檢查擺桿上的刀刃是否在刀承上,測力活塞頂端是否頂在鋼碗內(nèi),測力活塞上的小皮帶是否正常。并要檢查下鉗口升降限位開關(guān)及測力拉桿上負(fù)荷超載保護開關(guān)是否靈驗。 第四,試驗機每年應(yīng)該由法定機構(gòu)授權(quán)的技術(shù)機構(gòu)定期檢定一次,切不可過期使用。妃專業(yè)操作人員不要隨便開動試驗機,以免發(fā)生意外。
平時不用時應(yīng)主要保養(yǎng)試驗機,以延長試驗機的使用壽命。
YAW-300C全自動抗折抗壓試驗機技術(shù)參數(shù):
最大試驗力 300KN/10kN 試驗力示值相對誤差 ≤±1% 加荷速率 0.3KN/S~10KN/S(抗壓) 50N/s(抗折) 加荷速度誤差 ±5% 承壓板尺寸 φ155mm(抗壓) 80X150mm(抗折) 活塞最大行程 80mm 活塞直徑 φ130mm(抗壓) Φ60mm(抗折) 油液壓力 25MPa 油泵額定流量 1.52L/min 電機功率 0.75kW 主機外形尺寸㎜ 820×450×1300mm 主機重量 500Kg 售后服務(wù):一年三包,終生維修。詳情來電詳談。
關(guān)鍵詞:YAW-300C全自動抗折抗壓試驗機
This kit tests the level of samples rat GLP-7-37 by using a biotinylated double antibody sandwich enzyme-linked immunosorbent assay (ELISA) . Add GLP-7-37into the enzyme hole which has been previously coated with rat GLP-7-37 monoclonal antibody,then incubate; after incubation, add the biotin-labeled anti-GLP-7-37 antibodies, then combine it with streptavidin -HRP to form immune complexes, remove unbound enzyme through incubation and washing, and then add substrate a, B, produces blue,and convert into the final yellow in the action of acid . The depth of color has a positive correlation with the rats GLP-7-37 in the sample .
Kit Contents
|
| Name | 96holes configured 12×8 | 48holes configured 12×4 | notes |
| 1 | Standard:(80pg/ml) | 0.5ml | 0.5ml | Dilution ready to use |
| 2 | Microplate wells | 1 piece) | 1piece | Coated ready to use |
| 3 | Standard Diluent | 3ml | 3ml | Ready to use |
| 4 | Streptavidin -HRP | 6ml | 3ml | Ready to use |
| 5 | 30x washing Buffer | 20ml | 20ml | Distilled by water |
| 6 | Biotin-labeled anti-antibody -GLP-7-37 | 6ml | 3ml | Ready to use |
| 7 | Color agent A | 6ml | 3ml | Ready to use |
| 8 | Color agent B | 6ml | 3ml | Ready to use |
| 9 | Stop solution | 6ml | 3ml | Ready to use |
| 10 | Specification | one | one | Ready to use |
| 11 | Microplate Sealers | 2pieces | 2pieces | Disposable |
| 12 | Hermetic bag | one | one | Ready to use |
Reagents and equipment required but not supplied
1. Standard microplate reader ( filter with detection wavelength of 450nm , filter with calibration wavelength of 570nm or 630nm ).
2. The washer (injection fluid volume is adjustable to ensure that each hole can be added to 0.35ml lotion without overflow).
3. Benchtop, biological safety cabinet, fume hood.
4. The high-precision single-channel dosing device (range is 0.5-10μl, 2-20μl, 20-200μl, 200-1000μl).
5. 5. High-precision multi-channel dosing device (8 or 12 channels, the range is 50-300μl).
6 37 ℃ incubator.
7 The low temperature centrifuge.
8 Refrigerator (4 ℃, -20 ℃, -86 ℃).
9. Vortex mixer, low frequency oscillator, etc.
激光甲烷遙測檢測儀SA3C50A
一、概述◆ 天燃氣原料的泄漏給企業(yè)帶來巨大的經(jīng)濟損失◆ 天燃氣泄漏帶來了安全隱患◆ 遍布廠區(qū)的天燃氣管道檢測費工費時◆ 高空管道/狹窄區(qū)域管道難以檢測◆ 泄漏點難以準(zhǔn)確定位二、檢測原理激光甲烷探測器基于紅外吸收分光檢測原理,使用激光二極管作為光源。 由于激光可被甲烷進行吸收,測量時,將探測器指向目標(biāo)探測物如管道、地表,通過接收被反射回來的激光束來測量激光束的吸收系數(shù),從而實現(xiàn)檢測甲烷堆或泄漏的目的。探測器采用柱體密度(即甲烷密度PPM乘以甲烷柱體高度M) 作為測量單位。

相關(guān)儀,聽漏儀,管線定位儀,供水管道泄漏檢測設(shè)備,燃氣泄漏檢測儀,電纜故障測試儀,排水管道檢測儀,管道泄漏檢測,燃氣管道泄漏檢測,燃氣檢測車,燃氣手推車檢測,防腐層檢測儀,管線探測,管線普查,管線物探,管線定位,電纜檢測,電纜故障檢測檢測儀,耐壓測試儀,防腐檢測,埋地管道外防腐層檢測儀,管道檢測,非開挖導(dǎo)向,電纜燒弧儀,地質(zhì)雷達,清污車,清污設(shè)備,管道探測,在線檢測,內(nèi)窺檢測,管道疏通,測漏儀,管道機器人,管道內(nèi)窺鏡,測漏,燃氣檢測儀,乙烷辨識儀,色譜分析儀,管道內(nèi)窺,切管機,高壓測試儀,電纜測試車,管道檢測,檢漏儀,電纜故障定位,電纜測試設(shè)備,爬行器,檢測儀,應(yīng)急檢漏,漏水檢測工程,路面鉆孔機,路面打孔機,路面開孔機
校準(zhǔn):標(biāo)況【14.7psia(101.4kpa),70℉(21.1℃)】
重復(fù)性:±0.25%滿里程、
響應(yīng)時間:在滿里程25-100%范圍內(nèi),2秒內(nèi)達到2%精度
溫度系數(shù):0.15%滿里程/℃
壓力系數(shù):0.01%滿里程/psi(0.07bar)
氣體和周圍溫度:32℉-122℉(0℃-50℃),14℉-122℉(-10℃-50℃),干燥氣體
輸出信號:線性0-5Vdc(3000ohms最小負(fù)載阻抗);線性4-20mA(500ohms最大回路電阻)
傳感器輸入電源:通用+12...+26VDC,最大200mA
時間常數(shù):800ms
氣體壓力:最大1000psig(70bars)GFM17/37/47推薦使用20psig(1.4bars)
500psig(34.5bars)GFM57/67/77推薦使用20psig(1.4bars)
方位靈敏度:水平到垂直旋轉(zhuǎn)低于15度;標(biāo)準(zhǔn)校準(zhǔn)是在水平位置
連接:GFM17和37:1/4"卡套
GFM17可選6mm卡套,1/4"VCR,3/8"或1/8"卡套
GFM47:3/8"卡套
GFM57:3/8"卡套
GFM67:1/2"卡套
GFM77:3/4"FNPT或3/4"卡套
泄漏率:氦氣泄漏率1*109sml/s
CE認(rèn)證:EN55011class1,classB;EN50082-1