圖柏斯TruPulse200 高精度激光測(cè)距儀/測(cè)高儀 超強(qiáng)功能 | 商品編號(hào):108344 | ||||||||||||||||||||
價(jià) 格: ¥8850.00 市場(chǎng)價(jià): | |||||||||||||||||||||
!!如發(fā)現(xiàn)有別的正規(guī)網(wǎng)站價(jià)格比我們低,請(qǐng)告訴我們,我們核實(shí)后會(huì)為您調(diào)整價(jià)格。 | |||||||||||||||||||||
規(guī) 格: 測(cè)距1000/2000米 30厘米精度 測(cè)高測(cè)角 測(cè)目標(biāo)高度 存儲(chǔ) 傳輸接口 | |||||||||||||||||||||
|
產(chǎn)品詳細(xì)介紹
![]() | ![]() | |||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||
![]() |
HH-601A 高精度超級(jí)恒溫水。℉H-601A Super Constant Temperature Water-bathing) 介紹: |
高精度超級(jí)恒溫水浴采用進(jìn)口不銹鋼板及工藝生產(chǎn)制造,PID智能控溫,液晶顯示屏, 具有控溫精確度高,抗腐蝕性強(qiáng),結(jié)構(gòu)緊湊,造型美觀,節(jié)省能源,使用壽命長(zhǎng)等優(yōu)點(diǎn),適用于生物、植物、物理、化工、醫(yī)療、環(huán)保等實(shí)驗(yàn)科學(xué)領(lǐng)域直接或輔助加熱的精密儀器。 HH-601A Super Constant Temperature Water-bathing is made of stainless steel beard form abroad,and advaned technology.It hasvantages,such as controlling temperature precisely,strougly resisting corrosion,well-knit structure,beautiful surface,saving energy,long life etc. It’s precise instruments,suitable for direet or heating in experinent science biology,plant,physics,chenistry mdustry,science fieles,suehge,medical,environmental protection. |
HH-601A 高精度超級(jí)恒溫水浴 HH-601A Super Constant Temperature Water-bathing |
型 號(hào) TypeNo. | 控溫范圍(℃) Temperature Contrd Range(℃) | 功率(W) Power(W) | 工作尺寸 (cm) Working Size (cm) | 外形尺寸 (cm) Outside Size (cm) |
HH-601 | 室溫~100 (±0.1℃) | 1000 | 40×30×18 | 52×36×39 |
HH-601A | 室溫~100 (±0.05℃) | 1000 | 40×30×18 | 52×36×39 |
一:概述
HH-601A高精度超級(jí)恒溫水浴是采用進(jìn)口不銹鋼板及的工藝生產(chǎn)制造,各項(xiàng)技術(shù)指標(biāo)均達(dá)到國(guó)家標(biāo)準(zhǔn),是超級(jí)恒溫水浴的更新?lián)Q代產(chǎn)品。PID智能控溫,液晶顯示屏,它具有控溫精度高,抗腐蝕性強(qiáng),結(jié)構(gòu)緊湊,造型美觀,節(jié)省能源,使用壽命長(zhǎng)等優(yōu)點(diǎn),選用于生物,物理、植物、化工、醫(yī)療、環(huán)保等實(shí)驗(yàn)科學(xué)領(lǐng)域或輔助加熱的精密產(chǎn)品。
二:結(jié)構(gòu):
高精度超級(jí)恒溫水浴外殼采用金屬板,控制箱直接安裝在水箱上。旁邊有冷凝水管進(jìn)出水嘴兩只,水箱內(nèi)采用進(jìn)口水泵作為循環(huán)動(dòng)力,解決了溫水不勻的弊病,使儀器的控溫精度和水的均勻度都能達(dá)到較高的要求。
三:技術(shù)參數(shù):
1、電源 :220V 50Hz
2、溫度范圍:室溫+5℃—99.9℃
3, 溫度分辨率: 0.01℃
4, 控溫波動(dòng)范圍:≤0.05℃ 加熱功率1000w
5:恒溫設(shè)定與測(cè)量:PID智能控溫,液晶顯示屏,
6:水泵流速:≥4L/min 功率40w
7:總功耗 :≤ 1.2KW
8:工作尺寸:400X300X180
四 :使用方法
本儀器使用220V交流電源,請(qǐng)?jiān)谑褂们按_定電源插座額定電流不小于6A,并具有安全接地裝置(請(qǐng)使用時(shí)工作室內(nèi)接入接地裝置)。加水時(shí)請(qǐng)注意離上蓋板不低于8cm(超級(jí)恒溫水浴箱加水)必須用軟水,用蒸餾水,切勿使用井水、河水、泉水等硬水,以防加熱管爆裂及影響恒溫靈敏度。(注意先插儀器插口,再插電源插口)首先打開(kāi)電源,開(kāi)啟循環(huán)水泵,然后將恒溫部分的設(shè)定測(cè)量開(kāi)關(guān)打至需設(shè)定溫度(數(shù)顯),電源進(jìn)入ON指示,這時(shí)儀器已在加熱,待控溫指示進(jìn)入OFF時(shí),水箱水溫已達(dá)到了所設(shè)定的溫度,待水溫下降時(shí),指示又進(jìn)入加溫ON狀態(tài)“自動(dòng)控溫"。如需快速降低工作室溫,請(qǐng)關(guān)閉或調(diào)整數(shù)顯溫度設(shè)定指數(shù),外用乳膠管任意一頭接入冷水或自來(lái)水冷凝水嘴上,另一頭用乳膠管接入水池里進(jìn)行循環(huán)冷卻,水箱里的水將會(huì)很快冷凝下來(lái)。
五:注意事項(xiàng)
1、在使用前請(qǐng)?jiān)敿?xì)閱讀說(shuō)明書(shū),關(guān)閉水嘴千萬(wàn)記住先加水到水位線,再接通電源。2、 設(shè)置數(shù)顯溫度,打開(kāi)電源開(kāi)關(guān)使水箱升溫,蓋上水箱蓋,待水溫升到所需溫度值,打開(kāi)循環(huán)電源開(kāi)關(guān),水箱內(nèi)的水在循環(huán)均勻室內(nèi)溫度。3、 水位不能過(guò)高,以防止水溢出造成實(shí)驗(yàn)失誤。4、 不能過(guò)高,以防止水溢出造成實(shí)驗(yàn)失誤。5、 你需要快速降溫時(shí),控箱旁有二個(gè)水嘴,任意一個(gè)進(jìn)入冷凝水(制冰水或自來(lái)水),另一段進(jìn)入出水池(用乳膠管)協(xié)助降下當(dāng)時(shí)溫度。6、 為延長(zhǎng)儀器使用壽命,請(qǐng)注意勿將控制箱內(nèi)受潮,防止漏電。7、 儀器從出廠之日起保修一年(人為造成或使用不當(dāng)均收工本費(fèi)用),終身維修。8、使用結(jié)束請(qǐng)將水(出水嘴)放干凈,用干布擦拭干凈,置于通風(fēng)干燥處。
主要產(chǎn)品有:
1 、系列生化、光照、振蕩, 恒溫恒濕培養(yǎng)箱;2 、系列電子肺活量計(jì);3 、系列水浴恒溫振蕩器、氣浴恒溫振蕩器、全溫振蕩培養(yǎng)箱;4 、系列電子恒溫水浴鍋、三用恒溫水箱;5 、系列電動(dòng)離心機(jī);低速大容量離心機(jī);6 、系列恒溫磁力加熱攪拌器;7 、系列直流數(shù)顯恒速電動(dòng)攪拌器;8 、系列調(diào)速多用振蕩器;9 、系列石英亞沸蒸餾器;10、分析、防疫、環(huán)保儀器:一氧化碳測(cè)定儀、二氧化碳測(cè)定儀、數(shù)字式聲級(jí)計(jì)、測(cè)氡儀、極譜儀、測(cè)汞儀、甲醛分析儀、數(shù)字式照度計(jì)、數(shù)字式酸度計(jì)、數(shù)字式溫濕度計(jì)等;
定位儀微量注射泵是固定于腦立體定位儀或者顯微操作儀上,進(jìn)行腦內(nèi)注射應(yīng)用的儀器。能小注射量達(dá)到1pl,注射流速為0.05nl/min-520ul/min的超微量注射泵。可以直接夾持0.5ul到250ul容量的微量注射器,能匹配市面上大多數(shù)廠家生產(chǎn)的微量注射器型號(hào),只需要簡(jiǎn)單地從儀器的全觸屏微電腦控制器上選擇信息庫(kù)中對(duì)應(yīng)的注射器廠家和規(guī)格,即可實(shí)現(xiàn)準(zhǔn)確體積和流速的注射或回吸操作。主控制器為全觸屏,數(shù)據(jù)和進(jìn)程動(dòng)態(tài)顯示在大顯示屏上,數(shù)據(jù)設(shè)定直觀方便;主要特色:* 注射器可以精確控制注射量及注射速度;* 因?yàn)闆](méi)有很長(zhǎng)的導(dǎo)管,注射裝置及注射器直接安裝到定位儀的縱向軸上,液體直接從注射器的微量進(jìn)樣針針頭注入設(shè)定的位置,因而不易產(chǎn)生注射誤差;* 內(nèi)置注射器數(shù)據(jù)庫(kù),可以直接選擇使用的注射器;* 觸摸屏控制器,通過(guò)觸摸屏可進(jìn)行所有操作設(shè)置;* 包含電腦控制軟件,可通過(guò)電腦控制微注射泵的工作;產(chǎn)品特點(diǎn):微量注射泵可與腦立體定位儀配套使用,能過(guò)注射器直接對(duì)實(shí)驗(yàn)動(dòng)物注射,避免了采取塑料管方式產(chǎn)生的誤差;可以設(shè)定注射和吸收兩種工作方式;可注射/抽吸皮升及納升容量液體;多功能注射裝置:注該射泵可以設(shè)置1皮升注射容量;流速范圍0.05ul/min-520ul/min;可使用的注射器范圍0.5ul-250ul;微量注射泵的主要技術(shù)指標(biāo)如下:可配注射器型號(hào):1~100ul電源:220V,0.05A保險(xiǎn)管:5*20mm 微步進(jìn)電機(jī)動(dòng)力帶動(dòng)小步率:1步進(jìn)(1/2 step)大步率:400步進(jìn)/(1/2step)流速范圍:0.001-200ul/min(1-100ul注射器)尺寸:泵16.5x3x4.5cm(0.16kg) 控制器 23x15.2x7.6cm(2kg) 連接電纜180cm 安裝桿直徑8mm有兩種型號(hào)可供選擇:53311型,單通道配置,1臺(tái)主機(jī)搭配1個(gè)推進(jìn)器進(jìn)行微量注射53312型,雙通道配置,1臺(tái)主機(jī)控制2個(gè)推進(jìn)器,配合2個(gè)操作臂進(jìn)行微量注射
腦立體定位儀 通過(guò)加裝不同的 適配器,可以擴(kuò)展定位儀的功能,適應(yīng)更多的動(dòng)物種類(多種款式的腦立體定位儀適配器可供選擇,敬請(qǐng)來(lái)電咨詢)
可根據(jù)需要選擇小鼠腦立體定位儀、大鼠腦立體定位儀:
玉研儀器自主研發(fā)腦立體定位儀十四年,適用于大鼠、小鼠等實(shí)驗(yàn)動(dòng)物,經(jīng)典十字操作臂實(shí)現(xiàn)準(zhǔn)確定位,精度可達(dá)10微米,特制螺紋精密螺桿,穩(wěn)固不晃動(dòng)實(shí)現(xiàn)對(duì)特定腦區(qū)的精確定位,是神經(jīng)環(huán)路研究、神經(jīng)系統(tǒng)性疾病、神經(jīng)藥理等領(lǐng)域內(nèi)的重要研究設(shè)備,廣泛面向全國(guó)各大科研院校,醫(yī)院,高新企業(yè),藥企,醫(yī)療機(jī)構(gòu)等科研單位。大鼠腦立體定位儀、小鼠腦立體定位儀(雙臂腦立體定位儀,單臂腦立體定位儀,數(shù)顯型腦立體定位儀)(根據(jù)需求不同,有多種不同的型號(hào)可供選擇:?jiǎn)伪坌,雙臂型,數(shù)顯型,數(shù)控型,敬請(qǐng)來(lái)電咨詢)
輕便型:
標(biāo)準(zhǔn)型:
動(dòng)物腦立體定位儀產(chǎn)品特點(diǎn):操作靈活、簡(jiǎn)便,標(biāo)配大鼠適配器;腦立體定位儀標(biāo)尺是由激光雕刻,清晰易讀:手動(dòng)款式精確度為0.1mm,數(shù)字顯示型號(hào)精度為0.01mm;腦立體定位儀操作臂移動(dòng)范圍(上下,左右,前后):三方向移動(dòng)距離80mm;垂直方向可90度轉(zhuǎn)動(dòng),并隨時(shí)鎖定位置;擴(kuò)充能力很強(qiáng),可增加操作臂,增加注射裝置及顱鉆等;可以根據(jù)需要增加不同的固定器,用于多種動(dòng)物;腦立體定位儀具有以下優(yōu)勢(shì):
標(biāo)尺易讀數(shù)
移動(dòng)平滑
電生理操作方便
配件多樣,可選配各種動(dòng)物適配器,麻醉罩以及顱鉆
大鼠腦立體定位儀的主要構(gòu)造:數(shù)字顯示型腦立體定位儀Digital Stereotaxic Instrument 是一種可靠的多功能的設(shè)備,通過(guò)儀器的準(zhǔn)確定位,可以確保點(diǎn)擊、微管以及其它設(shè)備在實(shí)驗(yàn)過(guò)程中的精確定位。數(shù)顯型腦立體定位儀主要特點(diǎn):1.適用于小鼠、新生大鼠、鳥(niǎo)類等動(dòng)物的研究(請(qǐng)根據(jù)需求選擇合適的配置);2.無(wú)U型底座設(shè)計(jì),操作空間最大化;3.讀數(shù)精度采用游標(biāo)卡尺方式,讀數(shù)精度為10μm;4.操作臂上下、前后、左右移動(dòng)范圍可達(dá)80mm;垂直方向移動(dòng)90°可鎖;5.配有鼻子適配器、三種不同型號(hào)的耳棒等;6.三角形的導(dǎo)軌使之能夠進(jìn)行快速定位。其通用的接點(diǎn)便于實(shí)驗(yàn)者橫向或縱向移動(dòng)電極,鎖定裝置能夠?qū)㈦姌O以任何角度固定,不會(huì)滑脫。7.擴(kuò)充能力很強(qiáng),可增加操作臂、增加注射裝置及顱鉆等,也可以根據(jù)需要增加不同的固定器;8.目標(biāo)定位的調(diào)零功能:在任意一個(gè)位點(diǎn),每條軸方向上的顯示都可以歸零,這樣就可以使操作簡(jiǎn)化,閱讀方便。實(shí)際操作中,如果要定位一個(gè)特殊位點(diǎn),可以先找到參考點(diǎn),然后歸零,再移動(dòng)數(shù)顯型腦立體定位儀操作臂到希望到達(dá)的點(diǎn)上,調(diào)低電極,夾持器或微管到位點(diǎn)上即可。
小鼠及幼大鼠腦立體定位儀適配器
該小鼠適配器耳桿采用樹(shù)脂材料,對(duì)尖端進(jìn)行適合的錐度處理,能夠牢固的夾緊小鼠頭部又避免了采用不銹鋼作為耳桿對(duì)小鼠顱骨的損傷,兩側(cè)耳桿的高度和門(mén)齒夾的高度均可自由進(jìn)行調(diào)節(jié),并帶有刻度,適合不同的角度進(jìn)行實(shí)驗(yàn)。
多種型號(hào)可供選擇:
標(biāo)準(zhǔn)腦立體定位儀(小鼠)
雙臂標(biāo)準(zhǔn)腦立體定位儀(小鼠)
數(shù)顯標(biāo)準(zhǔn)腦立體定位儀(小鼠)
數(shù)顯雙臂標(biāo)準(zhǔn)腦立體定位儀(小鼠)
標(biāo)準(zhǔn)腦立體定位儀(大鼠)
雙臂標(biāo)準(zhǔn)腦立體定位儀(大鼠)
數(shù)顯標(biāo)準(zhǔn)腦立體定位儀(大鼠)
數(shù)顯雙臂標(biāo)準(zhǔn)腦立體定位儀(大鼠)
電動(dòng)標(biāo)準(zhǔn)腦立體定位儀(大鼠)
定位儀基座
大鼠頭部固定器
小鼠頭部固定器
SA-100系列 標(biāo)準(zhǔn)型大鼠腦立體定位儀:
SA-100系列 標(biāo)準(zhǔn)型小鼠腦立體定位儀:
SA-150系列 數(shù)顯型腦立體定位儀(大鼠)
單臂、數(shù)顯標(biāo)準(zhǔn)腦立體定位儀(小鼠)
雙臂、數(shù)顯雙臂標(biāo)準(zhǔn)腦立體定位儀(大鼠、小鼠)
腦立體定位儀相關(guān)配件及可選配件:
根據(jù)需要,還可以選擇頭部固定器:
大鼠腦部固定器適用于腦部固定的操作實(shí)驗(yàn), 同時(shí)配合氣體麻醉使用。非常適用于顯微鏡下對(duì)大鼠(小鼠有對(duì)應(yīng)的型號(hào))的手術(shù)操作和觀察實(shí)驗(yàn)使用。我們還可以提供核磁共振兼容型號(hào),供核磁環(huán)境中使用。
標(biāo)準(zhǔn)型大鼠頭部固定器:
小鼠腦室顯微觀察固定器
型號(hào):Y-AM-200
還可以加配跑輪,在小鼠運(yùn)行狀態(tài)下配合雙光子顯微鏡對(duì)腦室進(jìn)行成像和觀察:
型號(hào):Y-AM-210
小動(dòng)物腦立體定位儀部分參考文獻(xiàn):1. Albéri, L., Lintas, A., Kretz, R., Schwaller, B., & Villa, A. E. (2013). The calcium-binding protein parvalbumin modulates the firing 1 properties of the reticular thalamic nucleus bursting neurons. Journal of neurophysiology, 109(11), 2827-2841.2. Sonati, T., Reimann, R. R., Falsig, J., Baral, P. K., O’Connor, T., Hornemann, S., Aguzzi, A. (2013). The toxicity of antiprion antibodies is mediated by the flexible tail of the prion protein. Nature, 501(7465), 102-106.3. Ali, I., O’Brien, P., Kumar, G., Zheng, T., Jones, N. C., Pinault, D., O’Brien, T. J. (2013). Enduring Effects of Early Life Stress on Firing Patterns of Hippocampal and Thalamocortical Neurons in Rats: Implications for Limbic Epilepsy. PLOS ONE, 8(6), e66962.4. Bell, L. A., Bell, K. A., & McQuiston, A. R. (2013). Synaptic Muscarinic Response Types in Hippocampal CA1 Interneurons Depend on Different Levels of Presynaptic Activity and Different Muscarinic Receptor Subtypes. Neuropharmacology.5. Bolzoni, F., B?czyk, M., & Jankowska, E. (2013). Subcortical effects of transcranial direct current stimulation (tDCS) in the rat. The Journal of Physiology.6. Bolzoni, F., B?czyk, M., & Jankowska, E. (2013). Subcortical effects of transcranial direct current stimulation (tDCS) in the rat. The Journal of Physiology.7. Babaei, P., Tehrani, B. S., & Alizadeh, A. (2013). Effect of BDNF and adipose derived stem cells transplantation on cognitive deficit in Alzheimer model of rats. Journal of Behavioral and Brain Science, 3, 156-161.8. Gilmartin, M. R., Miyawaki, H., Helmstetter, F. J., & Diba, K. (2013). Prefrontal Activity Links Nonoverlapping Events in Memory. The Journal of Neuroscience, 33(26), 10910-10914.9. Feng, L., Sametsky, E. A., Gusev, A. G., & Uteshev, V. V. (2012). Responsiveness to nicotine of neurons of the caudal nucleus of the solitary tract correlates with the neuronal projection target. Journal of Neurophysiology, 108(7), 1884-1894.10. Clarner, T., Diederichs, F., Berger, K., Denecke, B., Gan, L., Van der Valk, P., Kipp, M. (2012). Myelin debris regulates inflammatory responses in an experimental demyelination animal model and multiple sclerosis lesions. Glia, 60(10), 1468-1480.11. Girardet, C., Bonnet, M. S., Jdir, R., Sadoud, M., Thirion, S., Tardivel, C., Troadec, J. D. (2011). Central inflammation and sickness-like behavior induced by the food contaminant deoxynivalenol: A PGE2-independent mechanism.Toxicological Sciences, 124(1), 179-191.12. Hru?ka-Plocháň, M., Juhas, S., Juhasova, J., Galik, J., Miyanohara, A., Marsala, M., Motlik, J. (2010). A27 Expression of the human mutant huntingtin in minipig striatum induced formation of EM48+ inclusions in the neuronal nuclei, cytoplasm and processes. Journal of Neurology, Neurosurgery & Psychiatry, 81(Suppl 1), A9-A9.13. Brooks, S., Jones, L., & Dunnett, S. B. (2010). A29 Frontostriatal pathology in the (C57BL/6J) YAC128 mouse uncovered by the operant delayed alternation task. Journal of Neurology, Neurosurgery & Psychiatry, 81(Suppl 1), A9-A10.14. Yu, L., Metzger, S., Clemens, L. E., Ehrismann, J., Ott, T., Gu, X., Nguyen, H. P. (2010). A28 Accumulation and aggregation of human mutant huntingtin and neuron atrophy in BAC-HD transgenic rat. Journal of Neurology, Neurosurgery & Psychiatry, 81(Suppl 1), A9-A9.15. Baxa, M., Juhas, S., Pavlok, A., Vodicka, P., Juhasova, J., Hru?ka-Plocháň, M., Motlik, J. (2010). A26 Transgenic miniature pig as an animal model for Huntington’s disease. Journal of Neurology, Neurosurgery & Psychiatry, 81(Suppl 1), A8-A9.
敬請(qǐng)關(guān)注玉研儀器微信號(hào):yuyanbio
DCCB帶型長(zhǎng)磁柵數(shù)顯裝置是我國(guó)目前大型機(jī)床處于正常使用狀態(tài)下最長(zhǎng)的的線性位移傳感器,填補(bǔ)了國(guó)內(nèi)大長(zhǎng)度直線位移傳感器制造的空白,經(jīng)上海市計(jì)量測(cè)試技術(shù)研究院測(cè)試和鑒定會(huì)實(shí)測(cè),該數(shù)顯裝置具有穩(wěn)定,安裝調(diào)試方便,精度高、壽命長(zhǎng)的優(yōu)點(diǎn),數(shù)顯裝置的非接觸式工作方式和串聯(lián)式磁頭結(jié)構(gòu)有創(chuàng)新,其綜合性能已經(jīng)達(dá)到國(guó)際同類型產(chǎn)品的水平。 行程: 2400mm up to 30000mm 規(guī)格: DCCB-240 ~DCCB-3000 精度: ±20 µm / 3m 分辨率: 1µm 最大響應(yīng)速度: 60m/min DCCB高精度、長(zhǎng)行程、非接觸式帶型磁柵尺與眾不同的特點(diǎn): 1, 全行程30米無(wú)接縫 采用申請(qǐng)專利的磁柵錄磁接長(zhǎng)技術(shù),30米內(nèi)任意長(zhǎng)度的磁帶(磁柵尺)都是整根向用戶提供,確保了在長(zhǎng)行程位移檢測(cè)中的精度和穩(wěn)定性。 2, 使用壽命長(zhǎng) 磁帶(磁柵尺)基體采用整體磁合金帶材,在工作區(qū)域內(nèi)磁帶與磁頭脫開(kāi)約0.05mm,從原理上排除了磨損壽命的問(wèn)題,提高了工作壽命。 應(yīng)用實(shí)例:重型機(jī)床、大型機(jī)械
| |||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||
簡(jiǎn)單介紹:
| |||||||||||||||||||||||||||||||||||||||||||||
典型應(yīng)用:
|
橫河2558A高精度交流電壓/電流源|沈陽(yáng)Yokogawa高精度交流電壓/電流源
YOKOGAWA 2558A交流標(biāo)準(zhǔn)電壓/電流源可以為儀表、鉗型表和電流傳感器的校準(zhǔn)提供簡(jiǎn)單、獨(dú)立的解決方案。2558A是一款經(jīng)濟(jì)實(shí)惠的高精密標(biāo)準(zhǔn)源,可以大量程輸出交流電壓和交流電流,適用于校準(zhǔn)各類電子測(cè)量?jī)x表。YOKOGAWA曾于1979年推出過(guò)2558交流標(biāo)準(zhǔn)電壓/電流源,這款標(biāo)準(zhǔn)源已于2003年停產(chǎn)。與老產(chǎn)品2558相比,今年新推出的2558A交流標(biāo)準(zhǔn)電壓/電流源在精度和其他性能方面均得到顯著提高。
YOKOGAWA 交流標(biāo)準(zhǔn)電壓/電流源2558A不但操作簡(jiǎn)單,還擁有值得客戶信賴的可靠性.
• 掃描(電壓/電流/頻率)
• 輸出分壓器
• 直接讀出偏差
• 數(shù)字顯示輸出
• 通用電流輸出端子
• 高精度
• 高穩(wěn)定性
• 大輸出量程
• 大頻率量程
交流電壓可輸出范圍可達(dá)1.00mV~1200.0V, 交流電流可輸出范圍可達(dá)1.00mA~60.A。因此,2558A適于校準(zhǔn)交流模擬儀表,可使校準(zhǔn)更具成本效益。通過(guò)旋鈕控制和多個(gè)計(jì)算機(jī)接口,2558A的前面板操作更加直觀,還可以利用ATE系統(tǒng)對(duì)其進(jìn)行控制。
高精度
交流電壓: +/- 0.04 %
交流電流: +/- 0.05 %
即使校準(zhǔn)0.1%精度級(jí)別的儀表,交流標(biāo)準(zhǔn)電壓/電流源2558A也完全可以勝任。
量程的10 ~ 120%
+/- (設(shè)置百分比 + 量程百分比)
50/60 Hz 40 < f < 400 Hz 400 < f< 1 kHz
交流電壓 0.03 to 0.01 0.05 to 0.01 0.10 to 0.02
交流電流 0.04 to 0.01 0.06 to 0.01 0.12 to 0.02
量程的1 ~ 10%
+/- (% of range)
50/60 Hz 40 < f < 400 Hz 400 < f< 1 kHz
交流電壓 0.013 0.015 0.03
交流電流 0.014 0.016 0.032
高穩(wěn)定性
交流電壓/電流: +/- 50 ppm/h
+/- (量程的20 ppm + 量程的30 ppm)/h
可長(zhǎng)時(shí)間執(zhí)行高重復(fù)性測(cè)量。
大輸出量程
交流電壓: 1.00 mV to 1200.0
交流電流: 1.00 mA to 60.00 A
6 電壓量程 (100 m/1/10/100/300/1000 ([V]))
4 電流量程 (100 m/1/10/50 ([A]))
發(fā)生范圍為量程的 0 to 144 %
大頻率范圍
40 ~ 1000Hz(頻率精度: ± 50ppm)
2558A既可以選擇50/60Hz(商用)和400Hz(航海和航空)的固定頻率,也可選擇40 ~ 1000Hz的可變頻率。
2558A(50ppm)的頻率精度極高,可以用于校準(zhǔn)各類頻率儀表。
通過(guò)內(nèi)部移相器,可使多臺(tái)2558A同步。這就意味著可將兩臺(tái)2558A當(dāng)作精確的電壓/電流源使用,用于校準(zhǔn)功率計(jì).
聯(lián)系人:吳先生
電話:15712324149
QQ:1596020710
郵箱:1596020710@qq.com
沈陽(yáng)子尊科技有限公司
聯(lián)系地址:沈陽(yáng)市沈河區(qū)萬(wàn)柳塘路105號(hào)甲5層
承接各種儀器儀表 歡迎電話咨詢
橫河2558A高精度交流電壓/電流源|沈陽(yáng)Yokogawa高精度交流電壓/電流源
原廠網(wǎng)站:www.numerikjena.de
北京高精度測(cè)厚儀PD-T1
本測(cè)厚儀采用脈沖反射超聲波測(cè)量原理,適用于超聲波能以一恒定速度在其內(nèi)部傳播,并能從其背面得到反射的各種材料厚度的測(cè)量。此儀器可對(duì)各種板材和各種加工零件作精確測(cè)量?蓮V泛應(yīng)用于石油、化工、冶金、造船、航空、航天等各個(gè)領(lǐng)域。
北京高精度測(cè)厚儀PD-T1
l采用高精度計(jì)時(shí)芯片實(shí)現(xiàn)精確的厚度測(cè)量
l智能語(yǔ)音播報(bào)
l內(nèi)置藍(lán)牙模塊,支持無(wú)線打印
l測(cè)量結(jié)果顯示分辨率為0.001mm和0.01mm可選
l測(cè)量誤差優(yōu)于0.03mm
lUSB2.0 接口
l液晶對(duì)比度可調(diào)
北京高精度測(cè)厚儀PD-T1:
l測(cè)量范圍:0.75-500mm(鋼).
l顯示精度:0.001mm
l測(cè)量誤差:1 mm~10 mm :±0.03mm 10mm~300mm :(±0.3%H+0.03)mm
l測(cè)量周期:4次/ 秒
l測(cè)量頻率:5MHz,2MHz
l聲速范圍:1000-9999m/s
l存儲(chǔ)容量:1000個(gè)厚度
l顯示: FSTN LCD顯示,帶冷光源照明顯示
l零位調(diào)整:探頭放在測(cè)厚儀試塊上按鍵自動(dòng)調(diào)零
l線性校正:微處理器程序自動(dòng)線性校正(即V Path 自動(dòng)補(bǔ)償)
l報(bào)警功能:可設(shè)置限界,對(duì)限界外的測(cè)量值能自動(dòng)蜂鳴報(bào)警
l工作電壓:3.7V 可充電鋰電池
l充電時(shí)間:4~5小時(shí)
l持續(xù)工作時(shí)間:150小時(shí)(不開(kāi)背光)
l自動(dòng)關(guān)機(jī):連續(xù)2分鐘無(wú)動(dòng)作自動(dòng)關(guān)閉,有開(kāi)關(guān)按鈕,待機(jī)時(shí)間可調(diào)
l顯示內(nèi)容:厚度值、耦合狀態(tài)、電量狀態(tài),可顯示CAL標(biāo)定狀態(tài)、聲速
l外形尺寸:132 X 76.2 mmX28 mm
l整機(jī)重量:253g
北京高精度測(cè)厚儀PD-T1
l適合測(cè)量金屬(如鋼、鑄鐵、鋁、銅等)、塑料、陶瓷、玻璃、玻璃纖維及其他任何超聲波的良導(dǎo)體的厚度;
l采用分級(jí)增益,可測(cè)鑄鐵;
l可配備多種不同頻率、不同晶片尺寸的探頭使用;
l具有探頭零點(diǎn)校準(zhǔn)、兩點(diǎn)校準(zhǔn)功能, 可對(duì)系統(tǒng)誤差進(jìn)行自動(dòng)修正;
l已知厚度可以反測(cè)聲速,以提高測(cè)量精度;
l具有單點(diǎn)測(cè)厚和掃描測(cè)厚多種測(cè)量模式;
l可預(yù)先設(shè)置厚度值上、下限,超出范圍自動(dòng)報(bào)警;
l具有耦合狀態(tài)提示功能;
l有LED背光顯示,方便在光線昏暗環(huán)境中使用;
l有剩余電量指示功能,可實(shí)時(shí)顯示電池剩余電量;
l帶有USB接口,與PC機(jī)通信;
l內(nèi)置藍(lán)牙模塊,支持無(wú)線打印;
l可選擇配備微機(jī)軟件,具有傳輸測(cè)量結(jié)果、存儲(chǔ)管理、統(tǒng)計(jì)分析、打印報(bào)告等豐富功能
1、58系列ATLANTA高精度伺服專用減速機(jī)
■特點(diǎn)(1) 低背隙(<2’)且可調(diào)整;(2) 高轉(zhuǎn)矩,最大輸出扭矩可達(dá)7000NM,比傳統(tǒng)同型減速機(jī)高70%;(3) 高轉(zhuǎn)速,輸入轉(zhuǎn)速可達(dá)3000r/min(部分機(jī)種可達(dá)5000r/min);(4) 標(biāo)準(zhǔn)中心距:(50、63、80、100、125)mm;(5) 寬泛的輸出減速比:I=4.75~52;(6) 壓力角:15º,齒接觸比2.0以上;(7) 中空軸輸出,可選用鍵/免鍵軸襯;(8) 具有5個(gè)安裝面,安裝自由;(9) 可與世界各種品牌伺服電機(jī)適配.
2、59系列ATLANTA經(jīng)濟(jì)型減速機(jī)
■特點(diǎn)(1)背隙在< 6’,不可調(diào)(2)標(biāo)準(zhǔn)中心距: 50; 63; 80; 100(3)最小中心距:32mm(4)3個(gè)安裝表面(5)表面光滑,適合食品工業(yè)(6)低噪聲(7)法蘭可替換,可適配不同廠家的伺服電機(jī)(8)整機(jī)采用通用可替換部件組裝