DNA-030K-22B 油電壓力開(kāi)關(guān)
DNA-040K-06I 油電壓力開(kāi)關(guān)
DNA-070K-22B 油電壓力開(kāi)關(guān)
DNA-100K-22B 壓力開(kāi)關(guān)16
DNA-250K-06I 油電 壓力開(kāi)關(guān)
DNA-250K-22B 油電 壓力開(kāi)關(guān)
DNB-040K-06I 油電 壓力開(kāi)關(guān)
DNB-040K-22B 油電壓力開(kāi)關(guān)
DNB-150K-06I 油電壓力開(kāi)關(guān)
DNB-150K-22B DNB-2 壓力開(kāi)關(guān)
DNC-040K-22B DNC-1 油電壓力開(kāi)關(guān)
DNC-250K-06I 油電壓力開(kāi)關(guān)
DNC-250K-22B 油電壓力開(kāi)關(guān)
DNF-040K-06I 油電壓力開(kāi)關(guān)
DNF-040K-22B 油電壓力開(kāi)關(guān)20
DNF-250K-06I 油電壓力開(kāi)關(guān)
DNF-250K-22B 油電壓力開(kāi)關(guān)
DNL-050K-06I 油電壓力開(kāi)關(guān)
DNL-400K-06I 油電壓力開(kāi)關(guān)
DNM-02W-40K-21B 油電壓力開(kāi)關(guān)
DNM-02W-40K-21B 油電壓力開(kāi)關(guān)
DNP-02K-06I 油電壓力開(kāi)關(guān)
TWOWAY壓力繼電器DNA-030K-22B DNA-040K-22B
主要用于電廠煙風(fēng)管路中作截流介質(zhì)之用,它具有全開(kāi)全關(guān)兩個(gè)功能,使系統(tǒng)某一管路介質(zhì)全部流通和關(guān)斷,它具有啟閉轉(zhuǎn)動(dòng)靈活,驅(qū)動(dòng)力矩小,有較高的嚴(yán)密性和能承受較大的工作壓力與工作溫度。風(fēng)門(mén)啟閉角度90度,啟閉時(shí)間小于或等于45秒。葉片關(guān)閉時(shí),其前后的密封效率可以達(dá)到99。85以上。
當(dāng)您打開(kāi)我們的網(wǎng)站,即是我們合作緣份的開(kāi)始,我們將萬(wàn)分珍惜您的厚愛(ài),在充滿(mǎn)商機(jī)挑戰(zhàn)的歲月里用最快捷,最優(yōu)惠,最安全的運(yùn)輸方式,將您的貨物運(yùn)送到您的客戶(hù)手中。,門(mén)對(duì)門(mén)服務(wù)、安全有保障、全程保險(xiǎn)、一路呵護(hù)。
鄭州到韶關(guān)市物流
★竭誠(chéng)為您服務(wù)!
李18638311137--13253661799------0371-----55919102【鄭州物流服務(wù)專(zhuān)線,只要價(jià)格合理沒(méi)有到達(dá)不了的地方,只要承諾過(guò)的必定、完成諾言 】
您的放心,是我們工作的力量;您的安心,是我們奮斗的目標(biāo);您的開(kāi)心,是我們服務(wù)的宗旨.
選擇鄭州物流 ---------
讓您放心,讓您安心,讓您省心,更讓您開(kāi)心的物物流專(zhuān)線
鄭州物物流有限專(zhuān)線—成功人士們的首選!
業(yè)務(wù)范圍:
1、承接各種大、中、小件貨運(yùn)的短途、中途、長(zhǎng)途運(yùn)輸業(yè)務(wù);
2、受理全國(guó)各地公路運(yùn)輸、鐵路運(yùn)輸、代理業(yè)務(wù)(*報(bào)關(guān)手續(xù));
3、為個(gè)人和企業(yè)提供長(zhǎng)途搬家服務(wù)業(yè)務(wù);
4、承接整車(chē)、零擔(dān)業(yè)務(wù);
5、整、散貨物的倉(cāng)儲(chǔ)和暫存、中轉(zhuǎn)服務(wù);
6、貴重物品、展會(huì)物資、易碎品軟包裝短途、中途、長(zhǎng)途運(yùn)輸;
7、普通、高級(jí)化妝品;鋼琴專(zhuān)業(yè)搬運(yùn)、包裝的運(yùn)輸業(yè)務(wù);
8、辦理如畫(huà)報(bào)、彩畫(huà)以及手工油畫(huà)的包裝及短途、中途、長(zhǎng)途運(yùn)輸業(yè)務(wù);
9、提供專(zhuān)業(yè)小轎車(chē)托運(yùn)業(yè)務(wù)物物流。
10、貨物運(yùn)輸保險(xiǎn)辦理;
服務(wù)標(biāo)準(zhǔn):
1、取緩本專(zhuān)線接到客戶(hù)委托兩小時(shí)內(nèi),安排相關(guān)人員上門(mén)取換
2、發(fā)緩所有貨物均按照不同的運(yùn)輸方式當(dāng)天上站、當(dāng)天發(fā)車(chē);
3、派送:貨到之后立即通報(bào)收貨人按時(shí)送貨上門(mén);
4、包裝:嚴(yán)格遵照外包裝圖標(biāo)要求進(jìn)行包裝、服務(wù)保障。
1、 通過(guò)服務(wù)網(wǎng)絡(luò)或傳真、電話準(zhǔn)時(shí)給客戶(hù)反饋承運(yùn)貨物的發(fā)貨情況、途中運(yùn)行情況及到貨情況。為客戶(hù)增加運(yùn)作透明度,解除后顧之憂;
2、 每一單貨物都會(huì)按客戶(hù)提供的收貨方電話,在貨物的到站的當(dāng)天與對(duì)方客戶(hù)及時(shí)聯(lián)系。通過(guò)傳真,電話或郵件通知對(duì)方準(zhǔn)確的提貨時(shí)間;
3、 隨車(chē)備有客戶(hù)信息反饋單,隨時(shí)了解運(yùn)輸過(guò)程中的意見(jiàn)和建議,可簽回單,同獅立客戶(hù)檔案、客戶(hù)走訪卡、定期走訪客戶(hù),了解客戶(hù)要求,完善我們的服務(wù)質(zhì)量;
4、 中國(guó)人民財(cái)產(chǎn)保險(xiǎn)股份有限專(zhuān)線保險(xiǎn)協(xié)議單位,可預(yù)約保險(xiǎn)、單獨(dú)出保單;
6、 速度快捷——每天準(zhǔn)時(shí)發(fā)車(chē),決不誤點(diǎn),隨時(shí)隨地與貨車(chē)保持緊密聯(lián)系;
7、 專(zhuān)人負(fù)責(zé)——每單業(yè)務(wù)均由專(zhuān)人洽淡、反饋、一到底;
8、 結(jié)帳靈活——可貨到付款批量貨運(yùn)可簽《長(zhǎng)期承運(yùn)合同》。
優(yōu)先選擇鄭州物流-----
-----您將獲得品牌對(duì)等的物流合作。
優(yōu)先選擇鄭州物流-----
-----您將獲得最具競(jìng)爭(zhēng)力的物流成本。
優(yōu)先選擇鄭州物流-----
-----您將享受最優(yōu)質(zhì)的物流服務(wù)。
可靠的信譽(yù),是本專(zhuān)線生存力量 低廉的價(jià)格,為您獲得更大利潤(rùn)
快捷的速度,為您節(jié)省更多時(shí)間 專(zhuān)項(xiàng)的保險(xiǎn),為您解決后顧之憂。
★ 、竭誠(chéng)為您服務(wù)!
★ ︴$客戶(hù)更省時(shí)、更省力、更省是鑫東方物流人孜孜不倦的追求︴$
︴$更安全,更快捷,更方便是鑫東方物流人對(duì)客戶(hù)最真誠(chéng)的承諾︴$
︴$準(zhǔn)時(shí)發(fā)車(chē),晝夜服務(wù),微笑待客,是鑫東方物流人的一貫準(zhǔn)則︴$
如有貨物需要從鄭州托運(yùn),請(qǐng)致電我們! 愿意與您全心合作,攜手并進(jìn),共創(chuàng)未來(lái)!鄭州到瀘州市物流專(zhuān)線;貨運(yùn)專(zhuān)線
專(zhuān)線地址--鄭州市南四環(huán)與鄭新路交叉口向西1000米路南
歡迎新老客戶(hù)來(lái)人來(lái)電洽談!真誠(chéng)期待與您的合作!互益互利,共求發(fā)展
嘉興哪有開(kāi)關(guān)量信號(hào)控制電子秤-200公斤控制放料電子磅稱(chēng)
“鼎拓衡器”只做高質(zhì)產(chǎn),絕不和劣質(zhì)產(chǎn)拼格,絕不降產(chǎn)的成本,分錢(qián)份貨,我們注重的是質(zhì),不會(huì)味的去追求廉的格而犧牲產(chǎn)的質(zhì)來(lái)吸引客戶(hù)。
開(kāi)關(guān)量信號(hào)控制電子秤功能點(diǎn):
—精確穩(wěn)定,LCD顯示字幕。
—可設(shè)精度高1/30000
—多種秤重單位及簡(jiǎn)易計(jì)數(shù),百分比計(jì)算功能,用途廣泛。
—采用充電,插電兩用方式供選擇,免除電源不穩(wěn)及停電困擾。
—具有單點(diǎn)校正及三點(diǎn)校正之功能
—具有累計(jì)重量并顯示功能,操作簡(jiǎn)單方便。
—具有重量警示功能,可設(shè)定上限,,下限三段重量警示,并具有組記憶功能
—具有自動(dòng)調(diào)整零點(diǎn)及軟件濾波功能,秤重反應(yīng)速度可依使用環(huán)境不同作調(diào)整
—RELAY接口,給出開(kāi)關(guān)量信號(hào),控制設(shè)備定量開(kāi)關(guān)。
—可選配:報(bào)警功能;三色警示燈;0-24mA/0-10v輸出接口帶控制;繼電器輸出接點(diǎn)等(歡迎來(lái)電咨詢(xún))
開(kāi)關(guān)量信號(hào)控制電子秤產(chǎn)功能:計(jì)重精確,去皮,重量累計(jì),簡(jiǎn)易計(jì)數(shù),公斤/磅單位轉(zhuǎn)換。選配功能:RS-232通訊接口,可以連接電腦和打印機(jī),開(kāi)關(guān)量信號(hào)和4-20mA電流控制信號(hào),三色報(bào)警燈可選。
售后服務(wù)內(nèi)容:
—免費(fèi)保修年限:凡屬于本公司之產(chǎn),產(chǎn)原因所發(fā)生的產(chǎn)之故障,均自購(gòu)買(mǎi)之日起憑保修單保修年。 —凡超出年的,均按收費(fèi)服務(wù),依故障狀況酌情收取零件、維修、校準(zhǔn)費(fèi)用。 —產(chǎn)使用過(guò)五年發(fā)生故障時(shí),本公司照常給予服務(wù),若本公司無(wú)零件庫(kù)存,則歉難服務(wù)。 —用戶(hù)所在地暫無(wú)維修單位的,請(qǐng)將產(chǎn)發(fā)至本公司修理
—蓄電池保用期三個(gè)月
上海鼎拓專(zhuān)業(yè)工業(yè)衡器制造商,可根據(jù)客戶(hù)要求定制各類(lèi)非標(biāo)電子衡器產(chǎn)!
統(tǒng)銷(xiāo)售服務(wù)熱線:021-57709403 13641981733
更多產(chǎn)詳情可登陸我司主網(wǎng)站:
網(wǎng)址:www.shdtsy.com
網(wǎng)址二:www.shdto.com
嘉興哪有開(kāi)關(guān)量信號(hào)控制電子秤-200公斤控制放料電子磅稱(chēng)
檢測(cè)原理
試劑盒采用雙抗體一步夾心法酶聯(lián)免疫吸附試驗(yàn)(ELISA)。往預(yù)先包被大鼠Runt相關(guān)基因 2(RUNX 2)捕獲抗體的包被微孔中,依次加入標(biāo)本、標(biāo)準(zhǔn)品、HRP標(biāo)記的檢測(cè)抗體,經(jīng)過(guò)溫育并洗滌。用底物TMB顯色,TMB在過(guò)氧化物酶的催化下轉(zhuǎn)化成藍(lán)色,并在酸的作用下轉(zhuǎn)化成最終的黃色。顏色的深淺和樣品中的大鼠Runt相關(guān)基因 2(RUNX 2)呈正相關(guān)。用酶標(biāo)儀在450nm 波長(zhǎng)下測(cè)定吸光度(OD 值),計(jì)算樣品濃度。
樣品收集、處理及保存方法
1. 血清:使用不含熱原和內(nèi)毒素的試管,操作過(guò)程中避免任何細(xì)胞刺激,收集血液后,3000轉(zhuǎn)離心10分鐘將血清和紅細(xì)胞迅速小心地分離。
2. 血漿:EDTA、檸檬酸鹽或肝素抗凝。3000轉(zhuǎn)離心30分鐘取上清。
3. 細(xì)胞上清液:3000轉(zhuǎn)離心10分鐘去除顆粒和聚合物。
4. 組織勻漿:將組織加入適量生理鹽水搗碎。3000轉(zhuǎn)離心10分鐘取上清。
5. 保存:如果樣本收集后不及時(shí)檢測(cè),請(qǐng)按一次用量分裝,凍存于-20℃,避免反復(fù)凍融,在室溫下解凍并確保樣品均勻地充分解凍。
自備物品
1. 酶標(biāo)儀(450nm)
2. 高精度加樣器及槍頭:0.5-10uL、2-20uL、20-200uL、200-1000uL
3. 37℃恒溫箱
操作注意事項(xiàng)
1. 試劑盒保存在2-8℃,使用前室溫平衡20分鐘。從冰箱取出的濃縮洗滌液會(huì)有結(jié)晶,這屬于正常現(xiàn)象,水浴加熱使結(jié)晶溶解后再使用。
2. 實(shí)驗(yàn)中不用的板條應(yīng)立即放回自封袋中,密封(低溫干燥)保存。
3. 標(biāo)準(zhǔn)品稀釋液即可視為陰性對(duì)照或者空白;預(yù)處理后的樣本無(wú)需稀釋?zhuān)苯尤?span>10μL加樣即可。
4. 嚴(yán)格按照說(shuō)明書(shū)中標(biāo)明的時(shí)間、加液量及順序進(jìn)行溫育操作。
5. 所有液體組分使用前充分搖勻。
試劑盒組成
| | | |
微孔酶標(biāo)板 | | | |
標(biāo)準(zhǔn)品(8ng/mL) | | | |
標(biāo)準(zhǔn)品稀釋液 | | | |
樣本稀釋液 | | | |
檢測(cè)抗體-HRP | | | |
20×洗滌緩沖液 | | | |
底物A | | | |
底物B | | | |
終止液 | | | |
封板膜 | | | |
說(shuō)明書(shū) | | | |
自封袋 | | | |
注:標(biāo)準(zhǔn)品用標(biāo)準(zhǔn)品稀釋液依次稀釋為:8、4、2、1、0.5、0.25 ng/mL
試劑的準(zhǔn)備
20×洗滌緩沖液的稀釋?zhuān)赫麴s水按1:20稀釋?zhuān)?span>1份的20×洗滌緩沖液加19份的蒸餾水。
洗板方法
1. 手工洗板:甩盡孔內(nèi)液體,每孔加滿(mǎn)洗滌液,靜置1min后甩盡孔內(nèi)液體,在吸水紙上拍干,如此洗板5次。
2. 自動(dòng)洗板機(jī):每孔注入洗液350μL,浸泡1min,洗板5次。
操作步驟
1. 從室溫平衡20min后的鋁箔袋中取出所需板條,剩余板條用自封袋密封放回4℃。
2. 設(shè)置標(biāo)準(zhǔn)品孔和樣本孔,標(biāo)準(zhǔn)品孔各加不同濃度的標(biāo)準(zhǔn)品50μL;
3. 待測(cè)樣本孔先加待測(cè)樣本10μL,再加樣本稀釋液40μL;
4. 隨后標(biāo)準(zhǔn)品孔和樣本孔中每孔加入辣根過(guò)氧化物酶(HRP)標(biāo)記的檢測(cè)抗體100μL,用封板膜封住反應(yīng)孔,37℃水浴鍋或恒溫箱溫育60min。
5. 棄去液體,吸水紙上拍干,每孔加滿(mǎn)洗滌液,靜置1min,甩去洗滌液,吸水紙上拍干,如此重復(fù)洗板5次(也可用洗板機(jī)洗板)。
6. 每孔加入底物A、B各50μL,37℃避光孵育15min。
7. 每孔加入終止液50μL,15min內(nèi),在450nm波長(zhǎng)處測(cè)定各孔的OD值。
結(jié)果判斷
繪制標(biāo)準(zhǔn)曲線:在Excel工作表中,以標(biāo)準(zhǔn)品濃度作橫坐標(biāo),對(duì)應(yīng)OD值作縱坐標(biāo),繪制出標(biāo)準(zhǔn)品線性回歸曲線,按曲線方程計(jì)算各樣本濃度值。
試劑盒性能
1. 性:標(biāo)準(zhǔn)品線性回歸與預(yù)期濃度相關(guān)系數(shù)R值,大于等于0.9900。
2. 靈敏度:檢測(cè)濃度小于0.01 ng/mL。
3. 特異性:不與其它可溶性結(jié)構(gòu)類(lèi)似物交叉反應(yīng)。
4. 重復(fù)性:板內(nèi)、板間變異系數(shù)均小于15%。
5. 貯藏:2-8℃,避光防潮保存。
6. 期:6個(gè)月
免責(zé)聲明
1. 試劑盒僅供研究使用,不得用于臨床實(shí)驗(yàn)或人體實(shí)驗(yàn),否則所產(chǎn)生的一切后果,由實(shí)驗(yàn)者承擔(dān),本公司概不負(fù)責(zé)。
2. 嚴(yán)格按照說(shuō)明書(shū)操作,實(shí)驗(yàn)者違反說(shuō)明書(shū)操作,后果由實(shí)驗(yàn)者承擔(dān)。
FOR RESEARCH USE ONLY.
NOT FOR USE IN DIAGNOSTIC PROCEDURES.
Intended use
This RUNX 2 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of RUNX 2 in the sample, this RUNX 2 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus RUNX 2 concentration. The concentration of RUNX 2 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Sample collection and storages
Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles
Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.
Materials required but not supplied
1. Standard microplate reader(450nm)
2. Precision pipettes and Disposable pipette tips.
3. 37 ℃ incubator
Precautions
1. Do not substitute reagents from one kit to another. Standard, conjugate and microplates are matched for optimal performance. Use only the reagents supplied by manufacturer.
2. Do not remove microplate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
3. Mix all reagents before using.
Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C)
Materials supplied
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
Note: Standard diluent with Standard diluent concentration was followed by:
8、4、2、1、0.5、0.25 ng/mL
Reagent preparation
Assay procedure
1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.
2. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.
3. Add Sample: Add testing sample 10μl Then add sample diluent 40μl to testing sample well; Blank well doesn’t add anyting.
4. Add 100μl of HRP-conjugate reagent to each well, cover with an adhesive strip and incubate for 60 minutes at 37°C.
4. Aspirate each well and wash, repeating the process four times for a total of five washes. Wash by filling each well with Wash Solution (400μl) using a squirt bottle, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting. Invert the plate and blot it against clean paper towels.
5. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.
6. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not
appear uniform, gently tap the plate to ensure thorough mixing.
7. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.
Calculation of results
1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
5. The sensitivity by this assay is 0.01 ng/mL.
6. Standard curve
Storage: 2-8℃.
validity: six months.
我司為德國(guó)KROHNE(科隆)大中華地區(qū)一級(jí)代理商. 15021002502 劉全:為您服務(wù)是我們的驕傲,歡迎來(lái)電垂詢(xún),對(duì)您的每一個(gè)詢(xún)問(wèn),我們?cè)诖讼绕谥轮x!產(chǎn)品述:科隆KROHNE流量開(kāi)關(guān)DW18系列 DW 181/182/183/184DW 18系列機(jī)械式流量開(kāi)關(guān)主要用于管道中的流量監(jiān)測(cè),廣泛應(yīng)用于壓縮機(jī)、電動(dòng)機(jī)、發(fā)電機(jī)、軋機(jī)、傳送器和其它機(jī)械的冷卻潤(rùn)滑系統(tǒng)中,可測(cè)量純凈或有微小顆粒的液體。當(dāng)流量超過(guò)一定值時(shí),輸出一開(kāi)關(guān)信號(hào),開(kāi)關(guān)可位于量程的任意位置上,具有較高的性和重復(fù)性。產(chǎn)品特點(diǎn):1.可安裝于水平和垂直的管道 2.1或2個(gè)流量限位開(kāi)關(guān)3.開(kāi)關(guān)重復(fù)性為±3%4.防護(hù)等級(jí)(指示器)IP555.可選螺紋或法蘭連接6.可選A型或G型指示器
H 250 是全金屬結(jié)構(gòu),可帶無(wú)磁滯后、無(wú)任何傳動(dòng)機(jī)構(gòu)變送器,可現(xiàn)場(chǎng)安裝氣阻尼裝置的模塊化金屬管浮子流量計(jì);谀K化設(shè)計(jì)設(shè)計(jì),遠(yuǎn)傳信號(hào)輸出,開(kāi)關(guān)信號(hào)輸出,累計(jì)量顯示,HART 協(xié)議執(zhí)行,Profibus-PA 總線,可以全部根據(jù)用戶(hù)需求即時(shí)安裝與使用。 高溫、高壓設(shè)計(jì),防腐材料選用,X-射線探傷,可以產(chǎn)品適用于任何現(xiàn)場(chǎng)需求。依據(jù)測(cè)量環(huán)境即可垂直安裝也可水平安裝,可采用法蘭連接,也可采用螺紋連接。始于1990年的生產(chǎn)與應(yīng)用經(jīng)驗(yàn),為您提供盡善盡美的服務(wù)。 H250 已經(jīng)廣泛應(yīng)用于石油,化工,冶金,電力,食品,制藥,造紙等行業(yè)的液體、氣體、蒸汽介質(zhì)的測(cè)量與過(guò)程控制""產(chǎn)品特點(diǎn):1.堅(jiān)固、簡(jiǎn)潔、設(shè)計(jì)2.模塊化、智能化指示器設(shè)計(jì)3.一次成型測(cè)量錐管4.陶瓷氣阻尼裝置5.堅(jiān)固、簡(jiǎn)潔、設(shè)計(jì)6.X-射線探傷7.低壓力損失設(shè)計(jì)8.短行程、小型結(jié)構(gòu)、250mm高 9.德國(guó)KROHNE 公司計(jì)算軟件計(jì)算10.介質(zhì)粘度,密度,溫度,壓力多級(jí)修正11.全進(jìn)口流量校驗(yàn)裝置產(chǎn)品精度12.100%壓力測(cè)試,100%產(chǎn)品校驗(yàn)13.多種指示器M7、M9、M10選擇 14.多種信號(hào)輸出:4-20mA;0.02-0.1MPa;開(kāi)關(guān)信號(hào)15.多種技術(shù)認(rèn)證質(zhì)量""技術(shù)參數(shù)
測(cè)量范圍 水:20℃ 25-100,000l/h空氣:1.013 bar abs 20℃ 0.7-600m3/h 精度等級(jí)(VDI/VDE 3513) H250/RR,H250/C4/Ti 1.6級(jí)(特殊多點(diǎn)校驗(yàn)后1.0級(jí))H250/PTFE 2.5級(jí)工作壓力 16-40bar介質(zhì)溫度 H250/RR,H250/C4/Ti -80℃~+300℃H250/PTFE -25℃~+70℃材質(zhì) 不銹鋼,哈氏合金,PTFE法蘭連接 DN15-DN100(特殊型DN300)防護(hù)等級(jí) IP 67儀表高度 法蘭連接(不包括密封墊圈) 250mm(特殊型300m)電流輸出(兩線制ESK) 4-20mA
開(kāi)關(guān)直流電源采用高頻電力電子開(kāi)關(guān)變換技術(shù)和多級(jí)閉環(huán)反饋控制技術(shù),交流電輸入后經(jīng)過(guò)整流、逆變、高頻變壓器、高頻整流濾波后輸出。上海蓄新電氣系列直流開(kāi)關(guān)電源具有動(dòng)態(tài)響應(yīng)快,過(guò)流能力強(qiáng),輸出紋波低,體積小、重量輕、效率高,操作簡(jiǎn)便。
高頻開(kāi)關(guān)電源功能介紹
具有穩(wěn)壓和穩(wěn)流兩種輸出模式
具有緊急停止功能,可瞬間停止電源輸出
具有RS232遠(yuǎn)程通訊控制功能,外部模擬量端口
其他特性
直流開(kāi)關(guān)電源控制接口(此項(xiàng)為選配項(xiàng))
1串行通訊接口
開(kāi)關(guān)直流電源選配RS232或RS485接口。通訊協(xié)議支持國(guó)際標(biāo)準(zhǔn)MODBUS通訊協(xié)議。
2外部模擬接口
支持0V~5V,0V~10V外部模擬電壓調(diào)節(jié)和檢測(cè)。
泄放裝置(此項(xiàng)為選配項(xiàng))
泄放裝置可用于電機(jī)在做試驗(yàn)測(cè)試時(shí)消耗電機(jī)產(chǎn)生的反沖能量,防止反沖電壓造成電機(jī)控制器損壞。
售后服務(wù):產(chǎn)品保修一年,終身維護(hù)。
包裝:標(biāo)準(zhǔn)工業(yè)包裝(紙箱,木箱,出口包裝)
產(chǎn)品名稱(chēng): 德國(guó)BECK930系列微差壓開(kāi)關(guān)產(chǎn)品型號(hào): 930