亚洲视频福利,日本精品一区二区三区在线,日韩欧美在线视频一区二区,国产高清自产拍av在线,99久久99久久精品国产片果冻,国产视频手机在线,成人禁在线观看午夜亚洲

ministat 125-1小反應(yīng)釜水浴

ministat 125-1小反應(yīng)釜水浴特點(diǎn)  —泵速可調(diào),更高壓力的壓力泵和吸收泵  —Ministat有3種型號,每個(gè)型號的壓縮機(jī)有水/氣冷兩種方式  —采用“即插即用”控制器  —槽內(nèi)外采用防化學(xué)腐蝕、容易清洗的不銹鋼;槽與支架之間沒有接縫,具有絕好的隔熱效果  —減少體積的插入物,減少內(nèi)循環(huán)體積,提高單位體積的功率  —加入矯正油浴附件,可以做精度為+0.01的矯正油浴  —3種面板操作方法相同,只要會一種,便可以操作所有的面板  ministat 125-1小反應(yīng)釜水浴特別適合250ml-2L的小反應(yīng)釜的溫控。  ministat 125-1小反應(yīng)釜水浴技術(shù)指標(biāo)  內(nèi)槽體積(L):2.75/1.3 加熱功率(KW):2.0 工作電壓(V):220 溫度范圍(℃):-25~200 制冷功率(KW):       20 ℃時(shí):0.3        0 ℃時(shí):0.21      -20 ℃時(shí):0.20 深度(mm):120 開口尺寸(mm):178*80 外形尺寸(mm):225*370*360 訂貨號:740.0001

Inspector Alert α、β、γ和X射線檢測儀

 儀器介紹

采用一只蓋革-彌勒計(jì)數(shù)管來測定α、β、γ和X射線輻射  “安全第一”(Safety First)的校準(zhǔn)功能能夠避免校準(zhǔn)人員的輻射接觸  檢測儀符合歐洲CE認(rèn)證要求 

主要特點(diǎn)

內(nèi)置鹵素淬滅劑GM探測器,對α、β射線源的靈敏度很高 四位液晶顯示,可選擇mR/hr、CPM、mSv/hr、CPS或Total/Timer等單位 總計(jì)數(shù)/定時(shí)器功能對輕微污染進(jìn)行定時(shí)的精確檢測,定時(shí)時(shí)間可選擇1分鐘--    24小時(shí)

技術(shù)參數(shù) 

測量范圍:mR/hr(毫倫/小時(shí)):0.001—110.0,CPM(每分鐘計(jì)數(shù)):0—300,000    μSv/hr(微希伏/小時(shí)):0.01—1,100,CPS(每秒鐘計(jì)數(shù)):0—5,000,總計(jì)數(shù):       1—9,999,000 效 率:Sr-90(546kev,2.3MeV βmax)約75%  C-14(156kev βmax)約11%    Bi-210(1.2MeV βmax)約64%  Am-241(5.5MeV α)約36% 靈 敏 度:3500CPM/ mR/hr(對于Cs-137) 精 度:±15% 溫度范圍:-10---+50 電 源:1節(jié)9V堿性電池,電池壽命 200小時(shí)尺寸重量:150×80×30mm 350克(含電池)

應(yīng)用領(lǐng)域

探測和測定表面沾污在操作放射性核素時(shí)監(jiān)測可能存在的放射性暴露量調(diào)查環(huán)境污染測定惰性氣體及其它低能放射性核素建筑裝飾材料放射測定 射線危害:低劑量的放射性射線輻射(天然背景輻射的變化范圍),對人體無害或風(fēng)險(xiǎn)甚低,但達(dá)到一定劑量則會對人體有害,可引起癌癥、白內(nèi)障、不孕癥、突變、萎縮效應(yīng)、壽命減短,甚至死亡

應(yīng)用:

偵測放射性射線,以采取相應(yīng)防護(hù)措施。海關(guān)和邊境巡邏,政府執(zhí)法部門,檢疫檢驗(yàn),應(yīng)急事故處理,核電廠、銀行、政府、實(shí)驗(yàn)室等部門安全巡查,醫(yī)學(xué)廢料處理,消防隊(duì),采礦業(yè),科學(xué)實(shí)驗(yàn),個(gè)人保護(hù),連續(xù)監(jiān)測

參考信息(來自中國輻射防護(hù)研究院)

居民的劑量限值為每年1mSv。即0.114μSv/hr。

放射性職業(yè)人員劑量限值為每年20mSv,但任何一年不能超過50mSv。

 

該公司產(chǎn)品分類: 核素識別儀 便攜式中子測量儀 便攜式β/γ/中子譜儀 電離室巡測儀 表面污染測量儀 多功能輻射測量儀 個(gè)人劑量報(bào)警儀 便攜式放射性監(jiān)測儀

ND-2100A型供應(yīng)北京ND-2100A型中文液晶實(shí)驗(yàn)室硅酸根表

 

ND-2100A型中文液晶實(shí)驗(yàn)室硅酸根表
 
ND-2106型實(shí)驗(yàn)室硅酸根表適用于樣水中微量硅酸根元素的定量測定。廣泛的運(yùn)用火力發(fā)電廠除鹽水蒸汽、凝結(jié)水爐水及化工、制藥等行業(yè)。
中文顯示,中文導(dǎo)引菜單,使操作極為方便,強(qiáng)大的功能組提供了許多新穎實(shí)用的功能。
 
上海博取ND-2100A實(shí)驗(yàn)室硅酸根表   功能特點(diǎn):
 
圖形液晶,全中文顯示
·功能眾多,菜單操作
·內(nèi)置實(shí)時(shí)時(shí)鐘,為存儲、標(biāo)定
·和記事等提供時(shí)間基準(zhǔn)
·內(nèi)置大容量存儲器,隨時(shí)存儲
·自動測量/手動輸入溫度
·特有的純水,加氨超純水25℃折算
·超純水自動溫度補(bǔ)償 ·微處理器智能化設(shè)計(jì)
·可手動輸入零點(diǎn)、斜率
·沒有可調(diào)器件、旋紐和波段開
·關(guān),更加穩(wěn)定。
·外殼采用增強(qiáng)ABS
·防水、防濕氣侵蝕,堅(jiān)固耐用。
·線路板與表殼沒有任何連線
·選配打印機(jī)T-LAB通訊及數(shù)據(jù)處理軟件
·在微機(jī)上進(jìn)行連續(xù)記錄和后期處理

 
ND-2100A實(shí)驗(yàn)室硅酸根表   技術(shù)參數(shù):
1.測量范圍:0~200μg/L,0~20mg/L(相互轉(zhuǎn)換)
2.分辨度:0.1          基本誤差:±2%F.S
3.重復(fù)性誤差:±2%F.S
4.穩(wěn)定性:±2%F.S/24h
5.被測水樣:0~60℃
6.時(shí)鐘精度:±1分/月
7.數(shù)據(jù)存儲數(shù)量:3000點(diǎn)
8.數(shù)據(jù)掉電連續(xù)保存時(shí)間:>5年
9.工作條件:環(huán)境溫度:0~60℃    相對濕度:<85%
10.電源:220V±10% 50±1 Hz
11.外形尺寸:310×210×100mm (長×寬×高)
該公司產(chǎn)品分類: COD分析儀 氟離子檢測儀 磷酸根/硅酸根分析儀 鈉度計(jì) 酸堿濃度計(jì) 濁度儀 余氯分析儀 電導(dǎo)率儀 PH計(jì) 溶氧儀

WNZ-500微機(jī)控制扭轉(zhuǎn)試驗(yàn)機(jī)500N.m

簡介:主要用于金屬或非金屬材料進(jìn)行扭轉(zhuǎn)強(qiáng)度測試,也可進(jìn)行各種零件,構(gòu)件抗扭強(qiáng)度試驗(yàn)。該機(jī)由主機(jī),控制系統(tǒng)和測量單元組成,可進(jìn)行扭矩控制,扭角控制雙閉環(huán)控制。軟件系統(tǒng):軟件采用虛擬儀器測試技術(shù),具有試驗(yàn)控制、數(shù)據(jù)采集、數(shù)據(jù)分析、編制報(bào)告等功能。主要技術(shù)指標(biāo): 扭矩測量范圍(Nm): 10-500扭轉(zhuǎn)測量精度: ≤±1%扭角顯示分辨率: 0.025°主動夾頭轉(zhuǎn)速(°/min): 4~500 加載速度(Nm/min): 0.1~100扭轉(zhuǎn)方向: 正、反兩個(gè)方向夾頭間距(mm): 0~600 可調(diào)節(jié)

AN218004DWDM光譜分析儀AN218004 [1526.05—1563.86 nm] SC/PC

DWDM光譜分析儀AN218004 [1526.05—1563.86 nm] SC/PC DWDM光譜分析儀特征:·PLC 設(shè)備· DWDM(96通道)測量解決方案· 同一時(shí)間自動測量 CWDM-96通道 (波長 & 功率) · CWDM 彩色圖文掃描· 保存和調(diào)用300數(shù)據(jù)· 軟件可以自行保存數(shù)據(jù)· 自動關(guān)機(jī)DWDM光譜分析儀技術(shù)參數(shù): 

技術(shù)參數(shù)

通道數(shù)量

96

通道間隔

50GHz, 100GHz

通道頻率

196.45~191.7THz

最大輸入功率

500mW; 27dBm

帶寬

1526.05~1563.86 nm

光源接頭

SC/PC Standard

測量速度

4 Sec. (all 96ch.)

電池

鋰聚合物電池, 1800毫安時(shí),3.7

測量范圍

+10~-40dBm

電池工作時(shí)長

充滿電后單次使用620分鐘

測量精度

± 1.0dB @ -40 dBm

電流消耗(Max)

0.25A

顯示屏分辨率

0.01dB

電力消耗

0.925W

顯示單位

dB, dBm,nm,THz

顯示

3.5” TFT-LCD, 16bit color, 240*320

重量

0.6 kg

尺寸

196*95*40 mm

溫度

(環(huán)境條件)

-20 to +55 °C (操作環(huán)境)

濕度

(最大無冷凝)

95%   (操作環(huán)境)

-35 to +65°C (儲存環(huán)境)

85%  (儲存環(huán)境)

http://www.yach.com/Instrument.html   更多光學(xué)儀器儀表
該公司產(chǎn)品分類: 衛(wèi)星天線 慣性導(dǎo)航系統(tǒng) 天線 微波射頻儀器 通訊儀器儀表 光通訊儀器儀表 光學(xué)儀器儀表 光通訊儀器儀表

電桿荷載位移測試儀專用拉力傳感器LH-N

1.拉式荷重傳感器。采用了箔式應(yīng)變片貼在合金鋼彈性體上,可用于拉、壓力值的測量,具有精度高、長期穩(wěn)定性好、密封性好、輸出對稱性好,抗偏載能力強(qiáng)。適用于各種電桿、排水管、管樁力學(xué)性能檢測。

2.量程:5\\\\10\\\\15\\\\20\\\\30\\\\50T 100\\\\150\\\\200300\\\\500T

3.綜合精度:0.05 %

4.靈敏度:2 ±0.1 mV /V

5.蠕變:±0.1F·S/30min

6.非線性:±0.1%F·S

7.滯后誤差:±0.1%F·S

8.重復(fù)性誤差:±0.1%F·S

9.零點(diǎn)溫度系數(shù):±0.1%F·S/10

10.輸出溫度系數(shù):±0.1%F·S/10

11.輸入阻抗:350±15Ω

12.輸出阻抗:350±15Ω

13.絕緣電阻:≥5000 MΩ

14.供橋電壓建議:10 VDC

15.工作溫度范圍: -20 - +70

16.允許過負(fù)荷: 150%F·S

17.密封等級: IP67

18.材質(zhì): 合金鋼

該公司產(chǎn)品分類: 耗材 壓力儀表 瓶類檢測儀 微型水泵,真空泵 電阻率測定儀 便攜式電測水位計(jì) 糧食水分測定儀 促銷產(chǎn)品 折光儀/折射儀 定氮儀,消煮爐 照度計(jì) 活性炭測試儀 晶閘管測試儀 可控硅控制器 焊接檢驗(yàn)尺 無菌檢查薄膜過濾器 管樁荷載測試儀

RI41德國hengstler編碼器

這款編碼器原產(chǎn)地德國,為了更好服務(wù)中國廣大客戶的需要,在天津設(shè)立了生產(chǎn)基地,德國hengstler歷史,品種多,采用進(jìn)的技術(shù)和的設(shè)計(jì)方案,了高質(zhì)量和性。

CSB-E04493h人血管緊張素Ⅱ(ANG-Ⅱ)ELISA Kit

1Human Angiotensin Ⅱ(ANG-Ⅱ)ELISA KitCatalog No. CSB-E04493h(96T) This immunoassay kit allows for the in vitro quantitative determination of humanANG-Ⅱ concentrations in serum, plasma. Expiration date six months from the date of manufacture FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.2PRINCIPLE OF THE ASSAYThe microtiter plate provided in this kit has been pre-coated with anantibody specific to ANG-Ⅱ. Standards or samples are then added to theappropriate microtiter plate wells with a biotin-conjugated polyclonalantibody preparation specific for ANG-Ⅱ and Avidin conjugated toHorseradish Peroxidase (HRP) is added to each microplate well andincubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solutionis added to each well. Only those wells that contain ANG-Ⅱ,biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit achange in color. The enzyme-substrate reaction is terminated by theaddition of a sulphuric acid solution and the color change is measuredspectrophotometrically at a wavelength of 450 nm ± 2 nm. Theconcentration of ANG-Ⅱ in the samples is then determined by comparingthe O.D. of the samples to the standard curve.DETECTION RANGE0.62ng/ml-40ng/ml. The standard curve concentrations used for the ELISA’swere40ng/ml, 20ng/ml, 10 ng/ml,5 ng/ml, 2.5 ng/ml, 1.25ng/ml,0.62 ng/ml.SPECIFICITYThis assay recognizes human ANG-Ⅱ. No significant cross-reactivity orinterference was observed.SENSITIVITYThe minimum detectable dose of human ANG-Ⅱ is typically less than0.16ng/ml.The sensitivity of this assay, or Lower Limit of Detection (LLD) was definedas the lowest protein concentration that could be differentiated from zero.3MATERIALS PROVIDEDReagent QuantityAssay plate 1Standard 2Sample Diluent 1 x 20 mlBiotin-antibody Diluent 1 x 10 mlHRP-avidin Diluent 1 x 10 mlBiotin-antibody 1 x 120μlHRP-avidin 1 x 120μlWash Buffer1 x 20 ml(25×concentrate)TMB Substrate 1 x 10 mlStop Solution 1 x 10 mlSTORAGE1. Unopened test kits should be stored at 2-8C upon receipt and themicrotiter plate should be kept in a sealed bag. The test kit may be usedthroughout the expiration date of the kit, provided it is stored asprescribed above. Refer to the package label for the expiration date.2. Opened test plate should be stored at 2-8C in the aluminum foil bagwith desiccants to minimize exposure to damp air. The kits will remainstable until the expiring date shown, provided it is stored as prescribedabove.3. A microtiter plate reader with a bandwidth of 10 nm or less and anoptical density range of 0-3 OD or greater at 450nm wavelength isacceptable for use in absorbance measurement.4REAGENT PREPARATIONBring all reagents to room temperature before use.1. Wash Buffer If crystals have formed in the concentrate, warm up toroom temperature and mix gently until the crystals have completelydissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized ordistilled water to prepare 500 ml of Wash Buffer.2. Standard Centrifuge the standard vial at 6000-10000rpm for 30s.Reconstitute the Standard with 1.0 ml of Sample Diluent. Thisreconstitution produces a stock solution of 40 ng/ml. Allow the standardto sit for a minimum of 15 minutes with gentle agitation prior to makingserial dilutions. The undiluted standard serves as the high standard (40ng/ml). The Sample Diluent serves as the zero standard (0 ng/ml).Prepare fresh for each assay. Use within 4 hours and discard after use.3. Biotin-antibody Centrifuge the vial before opening. Dilute to theworking concentration using Biotin-antibody Diluent(1:100),respectively.4. HRP-avidin Centrifuge the vial before opening. Dilute to the workingconcentration using HRP-avidin Diluent(1:100), respectively.Precaution: The Stop Solution provided with this kit is an acid solution. Weareye, hand, face, and clothing protection when using this material.OTHER SUPPLIES REQUIRED Microplate reader capable of measuring absorbance at 450 nm, withthe correction wavelength set at 540 nm or 570 nm. Pipettes and pipette tips. Deionized or distilled water. Squirt bottle, manifold dispenser, or automated microplate washer.5 An incubator which can provide stable incubation conditions up to37°C±0.5°C.SAMPLE COLLECTION AND STORAGE Serum Use a serum separator tube (SST) and allow samples to clotfor 30 minutes before centrifugation for 15 minutes at 1000 g. Removeserum and assay immediately or aliquot and store samples at -20°C.Centrifuge the sample again after thawing before the assay. Avoidrepeated freeze-thaw cycles. Plasma Collect plasma using citrate, EDTA, or heparin as ananticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes ofcollection. Assay immediately or aliquot and store samples at -20°C.Centrifuge the sample again after thawing before the assay. Avoidrepeated freeze-thaw cycles.Note: Grossly hemolyzed samples are not suitable for use in this assay.ASSAY PROCEDUREBring all reagents and samples to room temperature before use. It isrecommended that all samples, standards, and controls be assayed in duplicate.All the reagents should be added directly to the liquid level in the well. Thepipette should avoid contacting the inner wall of the well.1. Add 100μl of Standard, Blank, or Sample per well. Cover with theadhesive strip. Incubate for 2 hours at 37°C.2. Remove the liquid of each well, don’t wash.3. Add 100μl of Biotin-antibody working solution to each well. Incubatefor 1 hour at 37°C. Biotin-antibody working solution may appearcloudy. Warm up to room temperature and mix gently until solutionappears uniform.64. Aspirate each well and wash, repeating the process three times for atotal of three washes. Wash: Fill each well with Wash Buffer (200μl) andlet it stand for 2 minutes, then remove the liquid by flicking the plateover a sink. The remaining drops are removed by patting the plate on apaper towel. Complete removal of liquid at each step is essential togood performance.5. Add 100μl of HRP-avidin working solution to each well. Cover themicrotiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.6. Repeat the aspiration and wash three times as step 4.7. Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at37°C. Keeping the plate away from drafts and other temperaturefluctuations in the dark.8. Add 50μl of Stop Solution to each well when the first four wellscontaining the highest concentration of standards develop obvious bluecolor. If color change does not appear uniform, gently tap the plate toensure thorough mixing.9. Determine the optical density of each well within 30 minutes, using amicroplate reader set to 450 nm.CALCULATION OF RESULTSUsing the professional soft "Curve Exert 1.3" to make a standard curve isrecommended, which can be downloaded from our web.Average the duplicate readings for each standard, control, and sample andsubtract the average zero standard optical density. Create a standard curveby reducing the data using computer software capable of generating a fourparameter logistic (4-PL) curve-fit. As an alternative, construct a standardcurve by plotting the mean absorbance for each standard on the x-axisagainst the concentration on the y-axis and draw a best fit curve through the7points on the graph. The data may be linearized by plotting the log of theANG-Ⅱ concentrations versus the log of the O.D. and the best fit line canbe determined by regression analysis. This procedure will produce anadequate but less precise fit of the data. If samples have been diluted, theconcentration read from the standard curve must be multiplied by thedilution factor.LIMITATIONS OF THE PROCEDURE The kit should not be used beyond the expiration date on the kit label. Do not mix or substitute reagents with those from other lots or sources. It is important that the Standard Diluent selected for the standard curvebe consistent with the samples being assayed. If samples generate values higher than the highest standard, dilute thesamples with the appropriate Standard Diluent and repeat the assay. Any variation in Standard Diluent, operator, pipetting technique,washing technique, incubation time or temperature, and kit age cancause variation in binding. This assay is designed to eliminate interference by soluble receptors,binding proteins, and other factors present in biological samples. Untilall factors have been tested in the Immunoassay, the possibility ofinterference cannot be excluded.TECHNICAL HINTS Centrifuge vials before opening to collect contents. When mixing or reconstituting protein solutions, always avoid foaming. To avoid cross-contamination, change pipette tips between additions ofeach standard level, between sample additions, and between reagentadditions. Also, use separate reservoirs for each reagent.8 When using an automated plate washer, adding a 30 second soakperiod following the addition of wash buffer, and/or rotating the plate180 degrees between wash steps may improve assay precision. To ensure accurate results, proper adhesion of plate sealers duringincubation steps is necessary. Substrate Solution should remain colorless or light blue until added tothe plate. Keep Substrate Solution protected from light. SubstrateSolution should change from colorless or light blue to gradations ofblue. Stop Solution should be added to the plate in the same order as theSubstrate Solution. The color developed in the wells will turn from blueto yellow upon addition of the Stop Solution. Wells that are green incolor indicate that the Stop Solution has not mixed thoroughly with theSubstrate Solution.

該公司產(chǎn)品分類: 科研試劑

GM0120PQ1MNN美國米頓羅GM系列機(jī)械隔膜式計(jì)量泵

美國米頓羅GM系列機(jī)械隔膜式計(jì)量泵/GM0120米頓羅加藥泵/蘇州加藥泵

計(jì)量泵GM0050 /米頓羅GM0050/米頓羅計(jì)量泵GM0050/蘇州GM0050計(jì)量泵

GM0090米頓羅/GM0090計(jì)量泵/米頓羅計(jì)量泵GM0090/蘇州GM0090計(jì)量泵

米頓羅GM0120 /計(jì)量泵GM0120 /米頓羅計(jì)量泵GM0120/蘇州GM0120計(jì)量泵

米頓羅GM0170 /計(jì)量泵GM0170 /米頓羅計(jì)量泵GM0170/蘇州GM0170計(jì)量泵

GM0500米頓羅/GM0500計(jì)量泵/米頓羅計(jì)量泵GM0500/蘇州GM0500計(jì)量泵

 

主要型號包括:GM0050 GM0090 GM0120 GM0170 GM0240 GM0330 GM0400 GM0500

特點(diǎn):

平滑脈沖設(shè)計(jì),無沖擊 ? 沖程在靜態(tài)及動態(tài)條件下均可調(diào)節(jié)

多種材質(zhì)及泵頭結(jié)構(gòu)可選 ? 可選配電動沖程控制器

機(jī)械驅(qū)動PTFE膜片 ? 最大液體溫度40 ℃*

手動/ 自動沖程調(diào)節(jié)可選 ? 穩(wěn)態(tài)精度 +/- 2%(10%~100%)

沖程可調(diào)0~100%(自動/手動) ? 最大吸程4m水柱*

可選配電機(jī)控制器實(shí)現(xiàn)外部信號自動 控制, ? 最大吸入壓力:20m 水柱

電機(jī)頻率0~100%可調(diào)(GM泵 自動控制方式)

米頓羅機(jī)械隔膜泵,GMGB系列兩個(gè)系列。泵頭材質(zhì)為PVC,PPSS316,高粘度等可選擇,適合多種場合液體介質(zhì)的輸送。流量范圍從2.25L1800L均有。

 

可選雙隔膜泵頭結(jié)構(gòu)

建議維護(hù)周期: 自動控制方式選擇

電動沖程控制器接受外部控制信號,調(diào)節(jié)計(jì)量泵沖程長度, 從而改變計(jì)量泵輸出流量。

GM系列計(jì)量泵選擇ST型。 GB系列計(jì)量泵選擇ECC型。

變頻控制器:接受外部控制信號,調(diào)節(jié)計(jì)量泵沖程頻率,從而改變計(jì)量泵輸出流量。

供 電:220V/50HZ 單向

380V/50HZ 三相 控制信號:4~20mA 電機(jī)控制器(VARIPULSE):

僅用于GM系列計(jì)量泵,用于控制三相電機(jī),改變沖程頻率,從而調(diào)節(jié)計(jì)量泵輸出流量。

V 型-同計(jì)量泵一體式安裝   VR型-同計(jì)量泵分體式安裝

主要型號包括:GM0050 GM0090 GM0120 GM0170 GM0240 GM0330 GM0400 GM0500

上海 | 江蘇 | 浙江 | 安徽 | 福建 | 江西 | 山東 | 山西| 湖北 | 湖南 | 廣東 | 廣西 | 海南 | 重慶 | 四川 | 貴州 | 云南

 

 

 

蘇州米頓羅機(jī)械隔膜計(jì)量泵

1)*系列型號編碼

流量* L/h

壓力 MPa

沖程 spm

GM0002PL1MNN GM0005PL1MNN GM0010PL1MNN

2.25 4.5 9

1.2 1.2 1.2

36 72 144

GM0025PL1MNN GM0050PL1MNN

25 50

1.2 1.0

72 144

GM0090PQ1MNN GM0120PQ1MNN GM0170PQ1MNN GM0240PP1MNN

85 115 170 235

0.7 0.7 0.7 0.7

72 72 144 144

GM0330PP1MNN GM0400PP1MNN GM0500PP1MNN

315 400 500

0.5 0.5 0.5

144 144 180

上海 | 江蘇 | 浙江 | 安徽 | 福建 | 江西 | 山東 | 山西| 湖北 | 湖南 | 廣東 | 廣西 | 海南 | 重慶 | 四川 | 貴州 | 云南

特點(diǎn):

平滑脈沖設(shè)計(jì),無沖擊沖程在靜態(tài)及動態(tài)條件下均可調(diào)節(jié)

多種材質(zhì)及泵頭結(jié)構(gòu)可選可選配電動沖程控制器

機(jī)械驅(qū)動PTFE膜片最大液體溫度40 ℃

手動/ 自動沖程調(diào)節(jié)可選穩(wěn)態(tài)精度±2%(10%~100%)

沖程可調(diào)0~100%(自動/手動) •最大吸程4m水柱*

可選配電機(jī)控制器實(shí)現(xiàn)外部信號自動 控制,最大吸入壓力:20m 水柱

電機(jī)頻率0~100%可調(diào)(GM泵 自動控制方式)

可選雙隔膜泵頭結(jié)構(gòu)

建議維護(hù)周期:≤1.0MPa 4000h       

≤0.7MPa 8000h

自動控制方式選擇

電動沖程控制器 接受外部控制信號,調(diào)節(jié)計(jì)量泵沖程長度, 從而改變計(jì)量泵輸出流量。

GM系列計(jì)量泵選擇ST型。 GB系列計(jì)量泵選擇ECC型。

變頻控制器: 接受外部控制信號,調(diào)節(jié)計(jì)量泵沖程頻率,從而改變計(jì)量泵輸出流量。

 

供 電:220V/50HZ 單向

380V/50HZ 三相

控制信號:4~20mA

電機(jī)控制器(VARIPULSE):

僅用于GM系列計(jì)量泵,用于控制三相電機(jī),改變沖程頻率,從而調(diào)節(jié)計(jì)量泵輸出流量。

V 型-同計(jì)量泵一體式安裝

VR型-同計(jì)量泵分體式安裝

該公司產(chǎn)品分類: 塞瓦計(jì)量泵 新道茨NEWDOSE 日本安智邁計(jì)量泵 德普羅名特計(jì)量泵 SDP斯得浦計(jì)量泵 美帕斯菲達(dá)計(jì)量泵 意大利EMEC愛米克計(jì)量泵 TTbest精密計(jì)量泵 意大利道茨計(jì)量泵 意大利SEKO計(jì)量泵 米頓羅計(jì)量泵 力高計(jì)量泵 愛力浦計(jì)量泵 計(jì)量泵

ZARN50110-L-TV軸承FAG_ZARN50110-L-TV軸承尺寸

的專營進(jìn)口軸承銷售的企業(yè)之一,該公司是ZARN50110-L-TV軸承FAG授權(quán)代理商,專業(yè)銷售各種進(jìn)口軸承,主營品牌以瑞典SKF進(jìn)口軸承軸承型號查詢、德國FAG和INA、SKF軸承型號查詢?nèi)毡綨SK、美國TIMKEN為主等國際知名品牌的進(jìn)口軸承。歡迎來電咨詢ZARN50110-L-TV軸承尺寸、價(jià)格、技術(shù)支持或同型號其他品牌替換等詳細(xì)資料!如果您對FAGZARN50110-L-TV軸承有疑問,請聯(lián)系我們獲取更多ZARN50110-L-TV軸承的最新信息 FAG軸承。FAG供應(yīng)商供應(yīng)的產(chǎn)品主要用于機(jī)械制造、汽車、農(nóng)機(jī)、機(jī)床輕工日本IKO軸承、冶金、礦山機(jī)械、石油化工、等各行各業(yè)之中。聯(lián)系方式:電話 : 傳真: NADELLA滑塊ZARN50110-L-TV軸承 ZARN50110-L-TV軸承價(jià)格 ZARN50110-L-TV軸承尺寸ZARN50110-L-TV軸承報(bào)價(jià) ZARN50110-L-TV軸承圖片NADELLA軸承 【ZARN50110-L-TV軸承】尺寸參數(shù)表:軸承型號:ZARN50110-L-TV軸承內(nèi)徑:50 mm 外徑:110 mm 厚度:17,5 mm 品牌:FAG軸承系列:滾針/推力圓柱滾子軸承NADELLA線性模塊 上海東晟軸承有限公司提供FAG軸承ZARN50110-L-TV的軍工、針織機(jī)械、紡織輔助設(shè)備、氣動焊機(jī)、電泳槽、等技術(shù)參數(shù)。我公司本著“ 專業(yè)放心” 是我們的服務(wù)宗旨。為客戶提供快速、FAG軸承便捷、優(yōu)質(zhì)、專業(yè)的軸承型號查詢服務(wù)。我公司愿與您在平等互利的基礎(chǔ)上真誠合作共圖發(fā)展大計(jì)。推薦型號:NTNNUP2216軸承  NUP2217  NTN NUP2218E軸承  NTN NUP2218  NTNNUP2219E  NTNNUP2219軸承  NUP2220E  14118/14276-B軸承  26118-S/26283-B  3190/3120-B軸承  17119/17244-B  M86649/M86611-B軸承  2558/2523-B  3187/3120-B軸承  3191/3120-B  62302.2RSR  NU2204R軸承  639/632-B  61801-RS軸承  22352RHAKW33  6056M軸承  IKO軸承  德國NADELLA滑塊 公司網(wǎng)站:http://www.bearings365.comhttp://www.zcsearch.comhttp://www.sh-bearings.comhttp://www.zhoucheng188.comhttp://www.ikont.com.cnhttp://www.shdszc.com參考資料:http://www.zhoucheng188.com/FAG/ZARN50110-L-TV.html

 

 

該公司產(chǎn)品分類: 軸承

最新產(chǎn)品

熱門儀器: 液相色譜儀 氣相色譜儀 原子熒光光譜儀 可見分光光度計(jì) 液質(zhì)聯(lián)用儀 壓力試驗(yàn)機(jī) 酸度計(jì)(PH計(jì)) 離心機(jī) 高速離心機(jī) 冷凍離心機(jī) 生物顯微鏡 金相顯微鏡 標(biāo)準(zhǔn)物質(zhì) 生物試劑